Intracoronary Optical Coherence Tomography 2018: Current Status and Future Directions Fate of post-procedural malapposition of everolimus-eluting polymeric bioresorbable scaffold and everolimus-eluting cobalt chromium metallic stent in human coronary arteries: sequential assessment with optical coherence tomography in ABSORB Japan trial Optical coherence tomography findings: insights from the “randomised multicentre trial investigating angiographic outcomes of hybrid sirolimus-eluting stents with biodegradable polymer compared with everolimus-eluting stents with durable polymer in chronic total occlusions” (PRISON IV) trial Combining IVUS and Optical Coherence Tomography for More Accurate Coronary Cap Thickness Quantification and Stress/Strain Calculations: A Patient-Specific Three-Dimensional Fluid-Structure Interaction Modeling Approach Comparison of Stent Expansion Guided by Optical Coherence Tomography Versus Intravascular Ultrasound: The ILUMIEN II Study (Observational Study of Optical Coherence Tomography [OCT] in Patients Undergoing Fractional Flow Reserve [FFR] and Percutaneous Coronary Intervention) Optical coherence tomography imaging during percutaneous coronary intervention impacts physician decision-making: ILUMIEN I study Intracoronary Optical Coherence Tomography-Derived Virtual Fractional Flow Reserve for the Assessment of Coronary Artery Disease Optical coherence tomography compared with intravascular ultrasound and with angiography to guide coronary stent implantation (ILUMIEN III: OPTIMIZE PCI): a randomised controlled trial

Clinical Trial2013 Jan;165(1):65-72.

JOURNAL:Am Heart J. Article Link

A prospective, randomized trial of intravascular-ultrasound guided compared to angiography guided stent implantation in complex coronary lesions: the AVIO trial

Chieffo A, Latib A, Colombo A et al. Keywords: IVUS guided PCI; DES; outcome

ABSTRACT


BACKGROUND - No randomized studies have thus far evaluated intravascular ultrasound (IVUS) guidance in the drug-eluting stent (DES) era. The aim was to evaluate if IVUS optimized DES implantation was superior to angiographic guidance alone in complex lesions.


METHODS - Randomized, multicentre, international, open label, investigator-driven study evaluating IVUS vs angiographically guided DES implantation in patients with complex lesions (defined as bifurcations, long lesions, chronic total occlusions or small vessels). Primary study endpoint was post-procedure in lesion minimal lumen diameter. Secondary end points were combined major adverse cardiac events (MACE), target lesion revascularization, target vessel revascularization, myocardial infarction (MI), and stent thrombosis at 1, 6, 9, 12, and 24 months.


RESULTS - The study included 284 patients. No significant differences were observed in baseline characteristics. The primary study end point showed a statistically significant difference in favor of the IVUS group (2.70 mm ± 0.46 mm vs. 2.51 ± 0.46 mm; P = .0002). During hospitalization, no patient died, had repeated revascularization, or a Q-wave MI. No difference was observed in the occurrence of non-Q wave MI (6.3% in IVUS vs. 7.0% in angio-guided group). At 24-months clinical follow-up, no differences were still observed in cumulative MACE (16.9%vs. 23.2 %), cardiac death (0%vs. 1.4%), MI (7.0%vs. 8.5%), target lesion revascularization (9.2% vs. 11.9%) or target vessel revascularization (9.8% vs. 15.5%), respectively in the IVUS vs. angio-guided groups. In total, only one definite subacute stent thrombosis occurred in the IVUS group.


CONCLUSIONS - A benefit of IVUS optimized DES implantation was observed in complex lesions in the post-procedure minimal lumen diameter. No statistically significant difference was found in MACE up to 24 months.


TRIAL REGISTRATION -  ClinicalTrials.gov NCT00936169.