Randomized comparison of stent strut coverage following angiography- or optical coherence tomography-guided percutaneous coronary intervention Vascular response and healing profile of everolimus-eluting bioresorbable vascular scaffolds for percutaneous treatment of chronic total coronary occlusions: A one-year optical coherence tomography analysis from the GHOST-CTO registry Nonculprit Lesion Plaque Morphology in Patients With ST-Segment–Elevation Myocardial Infarction: Results From the COMPLETE Trial Optical Coherence Tomography Substudys Assessment and Quantitation of Stent Results by Intracoronary Optical Coherence Tomography Drug-eluting stent implantation in patients with acute coronary syndrome - the Activity of Platelets after Inhibition and Cardiovascular Events: Optical Coherence Tomography (APICE OCT) study A Survey on Coronary Atherosclerotic Plaque Tissue Characterization in Intravascular Optical Coherence Tomography Randomized Comparison Between Everolimus-Eluting Bioresorbable Scaffold and Metallic Stent: Multimodality Imaging Through 3 Years Superficial Calcium Fracture After PCI as Assessed by OCT

Clinical Trial2013 Jan;165(1):65-72.

JOURNAL:Am Heart J. Article Link

A prospective, randomized trial of intravascular-ultrasound guided compared to angiography guided stent implantation in complex coronary lesions: the AVIO trial

Chieffo A, Latib A, Colombo A et al. Keywords: IVUS guided PCI; DES; outcome

ABSTRACT


BACKGROUND - No randomized studies have thus far evaluated intravascular ultrasound (IVUS) guidance in the drug-eluting stent (DES) era. The aim was to evaluate if IVUS optimized DES implantation was superior to angiographic guidance alone in complex lesions.


METHODS - Randomized, multicentre, international, open label, investigator-driven study evaluating IVUS vs angiographically guided DES implantation in patients with complex lesions (defined as bifurcations, long lesions, chronic total occlusions or small vessels). Primary study endpoint was post-procedure in lesion minimal lumen diameter. Secondary end points were combined major adverse cardiac events (MACE), target lesion revascularization, target vessel revascularization, myocardial infarction (MI), and stent thrombosis at 1, 6, 9, 12, and 24 months.


RESULTS - The study included 284 patients. No significant differences were observed in baseline characteristics. The primary study end point showed a statistically significant difference in favor of the IVUS group (2.70 mm ± 0.46 mm vs. 2.51 ± 0.46 mm; P = .0002). During hospitalization, no patient died, had repeated revascularization, or a Q-wave MI. No difference was observed in the occurrence of non-Q wave MI (6.3% in IVUS vs. 7.0% in angio-guided group). At 24-months clinical follow-up, no differences were still observed in cumulative MACE (16.9%vs. 23.2 %), cardiac death (0%vs. 1.4%), MI (7.0%vs. 8.5%), target lesion revascularization (9.2% vs. 11.9%) or target vessel revascularization (9.8% vs. 15.5%), respectively in the IVUS vs. angio-guided groups. In total, only one definite subacute stent thrombosis occurred in the IVUS group.


CONCLUSIONS - A benefit of IVUS optimized DES implantation was observed in complex lesions in the post-procedure minimal lumen diameter. No statistically significant difference was found in MACE up to 24 months.