Abstract

Recommended Article

Rotational atherectomy in the subadventitial space to allow safe and successful chronic total occlusion recanalization: Pushing the limit further Rotational atherectomy and new-generation drug-eluting stent implantation Short-term and long-term clinical outcomes of rotational atherectomy in resistant chronic total occlusion Long-term outcomes of rotational atherectomy of underexpanded stents. A single center experience A Meta-Analysis of Contemporary Lesion Modification Strategies During Percutaneous Coronary Intervention in 244,795 Patients From 22 Studies Prevalence, Presentation and Treatment of 'Balloon Undilatable' Chronic Total Occlusions: Insights from a Multicenter US Registry Rotational Atherectomy Followed by Drug-Coated Balloon Dilation for Left Main In-Stent Restenosis in the Setting of Acute Coronary Syndrome Complicated with Right Coronary Chronic Total Occlusion Transverse partial stent ablation with rotational atherectomy for suboptimal culotte technique in left main stem bifurcation

Original Research2019 Mar 27. [Epub ahead of print]

JOURNAL:Catheter Cardiovasc Interv. Article Link

Characteristics of abnormal post-stent optical coherence tomography findings in hemodialysis patients

Matsuhiro Y, Matsunaga-Lee Y, Nakamura D et al. Keywords: chronic renal disease; coronary artery disease; OCT; stents

ABSTRACT


AIM - Clinical outcomes after percutaneous coronary intervention (PCI) in hemodialysis (HD) patients are significantly worse than those in non-HD patients. Optical coherence tomography (OCT) is a high resolution imaging modality and provides a detailed assessment of post-interventional abnormal findings that influence worse clinical outcomes. However, little is known about the abnormal post-stent OCT findings in HD patients. Therefore, in this study, we compared the abnormal post-stent OCT findings between HD and non-HD patients.


METHODS - One hundred thirty-nine consecutive OCT guided PCI (21 lesions in HD patients and 118 lesions in non-HD patients) were enrolled. We compared the post-stent OCT findings, including the edge dissections, under expansion index (minimum stent area/mean reference area), and stent eccentricity index (minimum stent diameter/maximum stent diameter) between HD and non-HD patients. We also compared the device-oriented clinical events (DoCEs) at 8 months of follow up.


RESULTS - There was a significantly higher prevalence of distal edge dissections (16.7% vs. 2.8%, P = 0.011) in HD patients. HD patients had a significantly lower under expansion index (0.76 ± 0.21 vs. 0.85 ± 0.14, P = 0.029) and stent eccentricity index (0.82 ± 0.09 vs. 0.88 ± 0.18, P = 0.018). The cumulative rate of DoCEs was significantly higher in the HD patients (23.8% vs. 5.2%, P = 0.013).


CONCLUSIONS - A higher prevalence of distal edge dissections, under expansion and stent eccentricity were detected by the detailed OCT findings in HD patients.

 