Two-Year Outcomes with a Magnetically Levitated Cardiac Pump in Heart Failure Positive recommendation for angiotensin receptor/neprilysin inhibitor: First medication approval for heart failure without "reduced ejection fraction" Clinical trial design and rationale of the Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3 (MOMENTUM 3) investigational device exemption clinical study protocol Frailty Is Intertwined With Heart Failure: Mechanisms, Prevalence, Prognosis, Assessment, and Management How to diagnose heart failure with preserved ejection fraction: the HFA-PEFF diagnostic algorithm: a consensus recommendation from the Heart Failure Association (HFA) of the European Society of Cardiology (ESC) Ambulatory Inotrope Infusions in Advanced Heart Failure - A Systematic Review and Meta-Analysis When and how to use SGLT2 inhibitors in patients with HFrEF or chronic kidney disease Sex Differences in Heart Failure With Preserved Ejection Fraction Pathophysiology: A Detailed Invasive Hemodynamic and Echocardiographic Analysis

Original Research2021 Jan 3.

JOURNAL:Clin Res Cardiol. Article Link

Predictors of high residual gradient after transcatheter aortic valve replacement in bicuspid aortic valve stenosis

G Bugani, M Pagnesi, D Tchetchè et al. Keywords: TAVR; balloon-expandable valve; bicuspid; high residual gradient; self-expandable valve;

ABSTRACT

OBJECTIVES - To define the incidence of high residual gradient (HRG) after transcatheter aortic valve replacement (TAVR) in BAVs and their impact on short term outcome and 1-year mortality.


BACKGROUND - Transcatheter heart valves (THVs) offer good performance in tricuspid aortic valves with low rate of HRG. However, data regarding their performance in bicuspid aortic valves (BAV) are still lacking.


METHODS - The BEAT (Balloon vs Self-Expandable valve for the treatment of bicuspid Aortic valve sTenosis) registry included 353 consecutive patients who underwent TAVR (Evolut R/PRO or Sapien 3 valves) in BAV between June 2013 and October 2018. The primary endpoint was device unsuccess with post-procedural HRG (mean gradient20 mmHg). The secondary endpoint was to identify the predictors of HRG following the procedure.


RESULTS - Twenty patients (5.6%) showed HRG after TAVR. Patients with HRG presented higher body mass index (BMI) (30.7 ± 9.3 vs. 25.9 ± 4.8; p < 0.0001) and higher baseline aortic mean gradients (57.6 ± 13.4 mmHg vs. 47.7 ± 16.6, p = 0.013) and more often presented with BAV of Sievers type 0 than patients without HRG. At multivariate analysis, BMI [odds ratio (OR) 1.12; 95% confidence interval (CI) 1.051.20, p = 0.001] and BAV type 0 (OR 11.31, 95% CI 3.4537.06, p < 0.0001) were confirmed as independent predictors of high gradient.


CONCLUSION - HRG following TAVR in BAVs is not negligible and is higher among patients with high BMI and with BAV 0 anatomy.