CBS 2019
CBSMD教育中心
中 文

肺动脉高压

Abstract

Recommended Article

Right ventricular stroke work correlates with outcomes in pediatric pulmonary arterial hypertension 中国肺高血压诊断和治疗指南2018 Sildenafil for improving outcomes in patients with corrected valvular heart disease and persistent pulmonary hypertension: a multicenter, double-blind, randomized clinical trial Bridging the Gap Between Epigenetic and Genetic in PAH Pulmonary artery denervation to treat pulmonary arterial hypertension: the single-center, prospective, first-in-man PADN-1 study (first-in-man pulmonary artery denervation for treatment of pulmonary artery hypertension) Risk Stratification in PAH Echocardiographic Screening for Pulmonary Hypertension in Congenital Heart Disease: JACC Review Topic of the Week rhACE2 Therapy Modifies Bleomycin-Induced Pulmonary Hypertension via Rescue of Vascular Remodeling

Original ResearchVolume 12, Issue 9, May 2019

JOURNAL:JACC Cardiovasc Interv. Article Link

5-Year Outcomes According to FFR of Left Circumflex Coronary Artery After Left Main Crossover Stenting

CH Lee, S-W Choi, JM Hwang et al. Keywords: left main stenting; outcome; FFR; Lcx

ABSTRACT

Objectives The aim of the current study was to evaluate the long-term clinical impact of fractional flow reserve (FFR) in jailed left circumflex coronary artery (LCx) after left main coronary artery (LM) simple crossover stenting.

Background Although the provisional side-branch intervention with FFR guidance has been validated for non-LM bifurcation lesions, the outcome of such a strategy in LM bifurcation disease is not well-known.

Methods Patients who underwent LM-to–left anterior descending coronary artery simple crossover stenting and who had FFR measurements in the LCx thereafter were enrolled. A low FFR was defined as ≤0.80. The clinical outcomes were assessed by the 5-year rate of target lesion failure (TLF) (a composite of cardiac death, target-vessel myocardial infarction, or target lesion revascularization).

Results In 83 patients, the mean FFR of the LCx after LM stenting was 0.87 ± 0.08, and 14 patients (16.9%) had a low FFR. There was no correlation between the FFR and angiographic % diameter stenosis in jailed LCx (R2 = 0.039; p = 0.071) and there was no difference in the angiographic % diameter stenosis in the high and low FFR groups. At 5 years, the low FFR group had a significantly higher rate of TLF than the high FFR group (33.4% vs. 10.7%; hazard ratio: 4.09, 95% confidence interval: 1.15 to 14.52; p = 0.029). However, there was no difference in the clinical outcomes according to the angiographic % diameter stenosis. In a multivariate analysis, a low FFR was an independent predictor of the risk for a 5-year TLF (hazard ratio: 6.49; 95% confidence interval: 1.37 to 30.73; p = 0.018).


Conclusions The patients with a high FFR in jailed LCx had better 5-year outcomes than those with a low FFR. The FFR measurement in jailed LCx can be helpful in selecting an adequate treatment strategy and may reduce unnecessary complex procedures.

简单支架技术横跨技术(crossover)

jailed Lcx 拘禁回旋支