CBS 2019
CBSMD教育中心
中 文

ASCVD Prevention

Abstract

Recommended Article

Diagnostic performance of noninvasive myocardial perfusion imaging using single-photon emission computed tomography, cardiac magnetic resonance, and positron emission tomography imaging for the detection of obstructive coronary artery disease: a meta-analysis Wearable Cardioverter-Defibrillator Therapy for the Prevention of Sudden Cardiac Death A Systematic Review and Meta-Analysis The Year in Cardiovascular Medicine 2020: Coronary Prevention: Looking back on the Year in Cardiovascular Medicine for 2020 in the field of coronary prevention is Professor Ramon Estruch, Dr Luis Ruilope, and Professor Francesco Cosentino. Mark Nicholls meets them Atherosclerosis — An Inflammatory Disease Impact of Abnormal Coronary Reactivity on Long-Term Clinical Outcomes in Women 2019 ESC/EAS Guidelines for the management of dyslipidaemias: lipid modification to reduce cardiovascular risk: The Task Force for the management of dyslipidaemias of the European Society of Cardiology (ESC) and European Atherosclerosis Society (EAS) Non-invasive detection of coronary inflammation using computed tomography and prediction of residual cardiovascular risk (the CRISP CT study): a post-hoc analysis of prospective outcome data Targeting the Immune System in Atherosclerosis: JACC State-of-the-Art Review

Clinical Trial2022 Mar 8;79(9):882-896.

JOURNAL:J Am Coll Cardiol. Article Link

2-Year Outcomes After Transcatheter Versus Surgical Aortic Valve Replacement in Low-Risk Patients

JK Forrest, GM Deeb, SJ Yakubov et al. Keywords: TAVR; aortic stenosis; low surgical risk; self-expanding supra-annular valve

ABSTRACT

BACKGROUND - The Evolut Low Risk Trial (Medtronic Evolut Transcatheter Aortic Valve Replacement in Low Risk Patients) showed that transcatheter aortic valve replacement (TAVR) with a supra-annular, self-expanding valve was noninferior to surgery for the primary endpoint of all-cause mortality or disabling stroke at 2 years. This finding was based on a Bayesian analysis performed after 850 patients had reached 1 year of follow-up.

 

OBJECTIVES - The goal of this study was to report the full 2-year clinical and echocardiographic outcomes for patients enrolled in the Evolut Low Risk Trial.

 

METHODS - A total of 1,414 low-surgical risk patients with severe aortic stenosis were randomized to receive TAVR or surgical AVR. An independent clinical events committee adjudicated adverse events, and a central echocardiographic core laboratory assessed hemodynamic endpoints.

 

RESULTS - An attempted implant was performed in 730 TAVR and 684 surgical patients from March 2016 to May 2019. The Kaplan-Meier rates for the complete 2-year primary endpoint of death or disabling stroke were 4.3% in the TAVR group and 6.3% in the surgery group (P = 0.084). These rates were comparable to the interim Bayesian rates of 5.3% with TAVR and 6.7% with surgery (difference -  -1.4%; 95% Bayesian credible interval: -4.9% to 2.1%). All-cause mortality rates were 3.5% vs 4.4% (P = 0.366), and disabling stroke rates were 1.5% vs 2.7% (P = 0.119), respectively. Between years 1 and 2, there was no convergence of the primary outcome curves.

 

CONCLUSIONS - The complete 2-year follow-up from the Evolut Low Risk Trial found that TAVR is noninferior to surgery for the primary endpoint of all-cause mortality or disabling stroke, with event rates that were slightly better than those predicted by using the Bayesian analysis. (Medtronic Evolut Transcatheter Aortic Valve Replacement in Low Risk Patients [Evolut Low Risk Trial]; NCT02701283).