CBS 2019
CBSMD教育中心
中 文

经导管主动脉瓣置换

Abstract

Recommended Article

Management of Asymptomatic Severe Aortic Stenosis: Evolving Concepts in Timing of Valve Replacement Transcatheter Aortic Valve Replacement: Role of Multimodality Imaging in Common and Complex Clinical Scenarios Balloon Aortic Valvuloplasty as a Bridge to Aortic Valve Replacement: A Contemporary Nationwide Perspective Transcatheter Aortic Valve Replacement in Low-Risk Patients With Symptomatic Severe Bicuspid Aortic Valve Stenosis Randomized Evaluation of TriGuard 3 Cerebral Embolic Protection After Transcatheter Aortic Valve Replacement: REFLECT II 2020 ACC Expert Consensus Decision Pathway on Management of Conduction Disturbances in Patients Undergoing Transcatheter Aortic Valve Replacement A Report of the American College of Cardiology Solution Set Oversight Committee 5-Year Outcomes Comparing Surgical Versus Transcatheter Aortic Valve Replacement in Patients With Chronic Kidney Disease 5-Year Outcomes After TAVR With Balloon-Expandable Versus Self-Expanding Valves: Results From the CHOICE Randomized Clinical Trial

Clinical Trial2019 Jan 15;139(3):337-346.

JOURNAL:Circulation. Article Link

Unloading the Left Ventricle Before Reperfusion in Patients With Anterior ST-Segment-Elevation Myocardial Infarction

Kapur NK, Alkhouli MA, DeMartini TJ et al. Keywords: heart failure; heart ventricles; heart-assist devices; myocardial infarction; reperfusion injury; door-to-balloon time

ABSTRACT


BACKGROUND - In ST-segment-elevation myocardial infarction (STEMI), infarct size correlates directly with heart failure and mortality. Preclinical testing has shown that, in comparison with reperfusion alone, mechanically unloading the left ventricle (LV) before reperfusion reduces infarct size and that 30 minutes of unloading activates a cardioprotective program that limits reperfusion injury. The DTU-STEMI pilot trial (Door-To-Unload in STEMI Pilot Trial) represents the first exploratory study testing whether LV unloading and delayed reperfusion in patients with STEMI without cardiogenic shock is safe and feasible.


METHODS - In a multicenter, prospective, randomized exploratory safety and feasibility trial, we assigned 50 patients with anterior STEMI to LV unloading by using the Impella CP followed by immediate reperfusion (U-IR) versus delayed reperfusion after 30 minutes of unloading (U-DR). The primary safety outcome was a composite of major adverse cardiovascular and cerebrovascular events at 30 days. Efficacy parameters included the assessment of infarct size by using cardiac magnetic resonance imaging.


RESULTS - All patients completed the U-IR (n=25) or U-DR (n=25) protocols with respective mean door-to-balloon times of 72 versus 97 minutes. Major adverse cardiovascular and cerebrovascular event rates were not statistically different between the U-IR versus U-DR groups (8% versus 12%, respectively, P=0.99). In comparison with the U-IR group, delaying reperfusion in the U-DR group did not affect 30-day mean infarct size measured as a percentage of LV mass (15±12% versus 13±11%, U-IR versus U-DR, P=0.53).


CONCLUSIONS - We report that LV unloading using the Impella CP device with a 30-minute delay before reperfusion is feasible within a relatively short time period in anterior STEMI. The DTU-STEMI pilot trial did not identify prohibitive safety signals that would preclude proceeding to a larger pivotal study of LV unloading before reperfusion. An appropriately powered pivotal trial comparing LV unloading before reperfusion to the current standard of care is required.


CLINICAL TRIAL REGISTRATION - URL: https://www.clinicaltrials.gov . Unique identifier: NCT03000270.