CBS 2019
CBSMD教育中心
中 文

经导管主动脉瓣置换

Abstract

Recommended Article

Randomized Evaluation of TriGuard 3 Cerebral Embolic Protection After Transcatheter Aortic Valve Replacement: REFLECT II Infective Endocarditis After Transcatheter Aortic Valve Replacement Extracellular Myocardial Volume in Patients With Aortic Stenosis Temporal Trends, Characteristics, and Outcomes of Infective Endocarditis After Transcatheter Aortic Valve Replacement Thrombotic Versus Bleeding Risk After Transcatheter Aortic Valve Replacement: JACC Review Topic of the Week Change in Kidney Function and 2-Year Mortality After Transcatheter Aortic Valve Replacement Impact of Pre-Existing and New-Onset Atrial Fibrillation on Outcomes After Transcatheter Aortic Valve Replacement Infective endocarditis after transcatheter aortic valve implantation: a nationwide study

Original Research2018 Oct 30. [Epub ahead of print]

JOURNAL:Eur Radiol. Article Link

Fractional flow reserve derived from CCTA may have a prognostic role in myocardial bridging

Zhou F, Tang CX, Zhang LJ et al. Keywords: cFFR; coronary CT angiography; myocardial bridging

ABSTRACT

PURPOSE - To evaluate the feasibility of fractional flow reserve (cFFR) derivation from coronary CT angiography (CCTA) in patients with myocardial bridging (MB), its relationship with MB anatomical features, and clinical relevance.


METHODS - This retrospective study included 120 patients with MB of the left anterior descending artery (LAD) and 41 controls. MB location, length, depth, muscle index, instance, and stenosis rate were measured. cFFR values were compared between superficial MB (2 mm), deep MB (> 2 mm), and control groups. Factors associated with abnormal cFFR values (0.80) were analyzed.


RESULTS - MB patients demonstrated lower cFFR values in MB and distal segments than controls (all p < 0.05). A significant cFFR difference was only found in the MB segment during systole between superficial (0.94, 0.90-0.96) and deep MB (0.91, 0.83-0.95) (p = 0.018). Abnormal cFFR values were found in 69 (57.5%) MB patients (29 [49.2%] superficial vs. 40 [65.6%] deep; p = 0.069). MB length (OR = 1.06, 95% CI 1.03-1.10; p = 0.001) and systolic stenosis (OR = 1.04, 95% CI 1.01-1.07; p = 0.021) were the main predictors for abnormal cFFR, with an area under the curve of 0.774 (95% CI 0.689-0.858; p < 0.001). MB patients with abnormal cFFR reported more typical angina (18.8% vs 3.9%, p = 0.023) than patients with normal values.


CONCLUSION - MB patients showed lower cFFR values than controls. Abnormal cFFR values have a positive association with symptoms of typical angina. MB length and systolic stenosis demonstrate moderate predictive value for an abnormal cFFR value. KEY POINTSMB patients showed lower cFFR values than controls. Abnormal cFFR values have a positive association with typical angina symptoms. MB length and systolic stenosis demonstrate moderate predictive value for an abnormal cFFR value .