CBS 2019
CBSMD教育中心
中 文

经导管主动脉瓣置换

Abstract

Recommended Article

Left Ventricular Hypertrophy and Clinical Outcomes Over 5 Years After TAVR: An Analysis of the PARTNER Trials and Registries Risk of Coronary Obstruction and Feasibility of Coronary Access After Repeat Transcatheter Aortic Valve Replacement With the Self-Expanding Evolut Valve: A Computed Tomography Simulation Study Comparison of newer generation self-expandable vs. balloon-expandable valves in transcatheter aortic valve implantation: the randomized SOLVE-TAVI trial Thrombotic Versus Bleeding Risk After Transcatheter Aortic Valve Replacement: JACC Review Topic of the Week Edoxaban versus Vitamin K Antagonist for Atrial Fibrillation after TAVR Valve‐in‐Valve for Degenerated Transcatheter Aortic Valve Replacement Versus Valve‐in‐Valve for Degenerated Surgical Aortic Bioprostheses: A 3‐Center Comparison of Hemodynamic and 1‐Year Outcome Transcatheter Aortic Valve Replacement in Patients With Multivalvular Heart Disease Comparison of 1-Year Pre- And Post-Transcatheter Aortic Valve Replacement Hospitalization Rates: A Population-Based Cohort Study

Original Research2019 May;12(5):e007448.

JOURNAL:Circ Cardiovasc Interv. Article Link

North American Expert Review of Rotational Atherectomy

Sharma SK, Tomey MI, Teirstein PS et al. Keywords: atherectomy; atherosclerosis; calcium; consensus; percutaneous coronary intervention

ABSTRACT


Rotational atherectomy (RA) is an established tool in interventional cardiology for treatment of calcified coronary lesions. Over 3 decades of clinical experience and research, techniques have matured and outcomes have improved. Heterogeneity exists, however, in RA utilization and technique. We assembled a group of experienced RA operators and device experts to summarize and critique key elements of contemporary RA technique, to identify areas of consensus and controversy, and to offer recommendations for optimal performance for the practicing interventional cardiologist. Evolution in RA strategy toward a focus on lesion modification to facilitate balloon angioplasty and stenting has underpinned major advances in procedural safety, including opportunity to use smaller caliber equipment and radial access. Optimal technique and improved safety have permitted exploratory use of RA for different lesion types and reevaluation of procedural requirements, including flush solution composition and transvenous pacing. Preparedness to manage complications remains paramount and recommendations for operators and institutions are outlined.