CBS 2019
CBSMD教育中心
中 文

Transcatheter Aortic Valve Replacement

Abstract

Recommended Article

Transcatheter aortic-valve replacement with a self-expanding prosthesis 2020 ACC/AHA Guideline for the Management of Patients With Valvular Heart Disease: A Report of the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines Predictors and Clinical Outcomes of Next-Day Discharge After Minimalist Transfemoral Transcatheter Aortic Valve Replacement Transcatheter Aortic Valve Replacement in Patients With Multivalvular Heart Disease Conscious Sedation Versus General Anesthesia for Transcatheter Aortic Valve Replacement: Variation in Practice and Outcomes Long-Term Durability of Transcatheter Heart Valves: Insights From Bench Testing to 25 Years Contemporary real-world outcomes of surgical aortic valve replacement in 141,905 low-risk, intermediate-risk, and high-risk patients Early Surgery or Conservative Care for Asymptomatic Aortic Stenosis

Original Research

JOURNAL:ACC Article Link

Tricuspid Clip in Tricuspid Regurgitation

Gilbert Hin-Lung Tang, MD, MSC, MBA, FACC

Pre-reading

Severe tricuspid regurgitation (TR), whether symptomatic or asymptomatic, is predictive of poor survival if left untreated. Medical therapy, consisting mostly of diuretics, is of limited efficacy. Clinical sequelae, including right heart dysfunction, peripheral edema, and liver congestion, confer a poor quality of life and poor prognosis. Surgical tricuspid repair and replacement have significant mortality and morbidity risks due to patient comorbidities and poor right heart function.

Transcatheter tricuspid valve repair is an emerging alternative to medical therapy and surgery to manage patients with symptomatic severe TR. Several technologies are currently in clinical trials, including edge-to-edge repair, annuloplasty repair, and de novo replacement (Figure 1). The MitraClip device (Abbott Structural Heart; Santa Clara, CA) has been used to repair the tricuspid valve in an off-label manner in over 1,000 cases worldwide with excellent safety and good efficacy, as evidenced by multicenter retrospective studies and the TriValve Registry. The TRILUMINATE (Evaluation of Treatment With Abbott Transcatheter Clip Repair System in Patients With Moderate or Greater Tricuspid Regurgitation) global feasibility study, consisting of sites from the European Union and United States, evaluated transcatheter tricuspid valve repair using the TriClip system (Abbott Structural Heart; Santa Clara, CA). The 1-year outcomes, presented at the 2019 PCR London Valves Annual Meeting, showed excellent safety and efficacy of the TriClip system in terms of TR reduction, low mortality, improvement in quality of life, and right atrial and ventricular modeling (Figures 2-3).1


Figure 1: Transcatheter Tricuspid Therapy Landscape


Figure 2


Figure 3


Imaging the tricuspid valve can be challenging. Transesophageal echocardiography (TEE) is the primary modality used to optimize leaflet grasping and assessment of insertion (Figure 4). Intracardiac echocardiography (ICE) can be a valuable complementary imaging tool to confirm leaflet insertion (Figure 5).2 The TRILUMINATE Pivotal Trial is currently ongoing, randomizing patients with symptomatic severe TR to medical therapy or TriClip or utilizing TriClip as a treatment arm if the TR can be reduced by only one grade in severity.

Figure 4


Figure 5



References

  1. Nickenig G, on behalf of the TRILUMINATE investigators. Percutaneous edge-to-edge repair for tricuspid regurgitation: Initial 1-year outcomes from the TRILUMINATE clinical trial. Presented at PCR London Valves 2019; November 18, 2019.
  2. Tang GH, Yakubov SJ, Sanchez Soto CE. Four-Dimensional Intracardiac Echocardiography in Transcatheter Tricuspid Valve Repair With the MitraClip System. JACC Cardiovasc Imaging 2020;Jan 9:[Epub ahead of print].