CBS 2019
CBSMD教育中心
English

推荐文献

科研文章

荐读文献

Percutaneous coronary intervention using a combination of robotics and telecommunications by an operator in a separate physical location from the patient: an early exploration into the feasibility of telestenting (the REMOTE-PCI study) Development and validation of a simple risk score to predict 30-day readmission after percutaneous coronary intervention in a cohort of medicare patients Long-Term Outcomes of Biodegradable Versus Second-Generation Durable Polymer Drug-Eluting Stent Implantations for Myocardial Infarction 稳定性冠心病诊断与治疗指南 Efficacy and safety of rosuvastatin vs. atorvastatin in lowering LDL cholesterol : A meta-analysis of trials with East Asian populations Association between urinary dickkopf-3, acute kidney injury, and subsequent loss of kidney function in patients undergoing cardiac surgery: an observational cohort study Derivation and Validation of a Chronic Total Coronary Occlusion Intervention Procedural Success Score From the 20,000-Patient EuroCTO Registry:The EuroCTO (CASTLE) Score Mortality 10 Years After Percutaneous or Surgical Revascularization in Patients With Total Coronary Artery Occlusions Mode of Death in Heart Failure With Preserved Ejection Fraction Advances in Coronary No-Reflow Phenomenon-a Contemporary Review

Original ResearchAugust 2019 Vol 12, Issue 8

JOURNAL:Circ Cardiovasc Interv. Article Link

Long-Term Effect of Ultrathin-Strut Versus Thin-Strut Drug-Eluting Stents in Patients With Small Vessel Coronary Artery Disease Undergoing Percutaneous Coronary Intervention: A Subgroup Analysis of the BIOSCIENCE Randomized Trial

JF Iglesias, D Heg , M Roffi et al.

ABSTRACT


BACKGROUND - Randomized trials evaluating the Orsiro biodegradable polymer sirolimus-eluting stent (BP-SES; 60 and 80 μm strut thickness for stent diameters 3 and >3 mm, respectively) did not stratify according to vessel size and failed to specify the impact of ultrathin-strut thickness on long-term clinical outcomes compared with durable polymer everolimus-eluting stents (DP-EES). We sought to assess the long-term effect of ultrathin-strut (60 μm) BP-SES versus thin-strut (81 μm) DP-EES on long-term outcomes in patients undergoing percutaneous coronary revascularization for small vessel disease.

 

METHODS - In a subgroup analysis of the randomized, multicenter, noninferiority BIOSCIENCE trial, patients with stable coronary artery disease or acute coronary syndrome randomly assigned to treatment with BP-SES or DP-EES were stratified according to vessel size (3 mm versus >3 mm) as a surrogate to compare patients treated with ultrathin-strut versus thin-strut drug-eluting stent. The primary end point was target lesion failure, a composite of cardiac death, target vessel myocardial infarction, and clinically indicated target lesion revascularization, within 5 years.

 

RESULTS - Among 2109 patients, 1234 (59%) were treated for small vessel disease. At 5 years, target lesion failure occurred in 124 patients (cumulative incidence, 22.3%) treated with ultrathin-strut BP-SES and 109 patients (18.3%) treated with thin-strut DP-EES (rate ratio, 1.22; 95% CI, 0.941.58; P=0.13). Cumulative incidences of cardiac death, target vessel myocardial infarction, and clinically indicated target lesion revascularization and definite stent thrombosis at 5 years were similar in patients treated with ultrathin-strut BP-SES and thin-strut DP-EES. After adjustment for potential confounders, there was no significant interaction between vessel size and treatment effect of BP-SES versus DP-EES.

 

CONCLUSIONS - We found no significant difference in clinical outcomes throughout 5 years between patients with small vessel disease treated with ultrathin-strut BP-SES versus thin-strut DP-EES.

 

CLINICAL TRIAL REGISTRATION - URL: https://www.clinicaltrials.gov. Unique identifier: NCT01443104.