CBS 2019
CBSMD教育中心
English

推荐文献

科研文章

荐读文献

The Astronaut Cardiovascular Health and Risk Modification (Astro-CHARM) Coronary Calcium Atherosclerotic Cardiovascular Disease Risk Calculator 2019 AHA/ACC/HRS Focused Update of the 2014 AHA/ACC/HRS Guideline for the Management of Patients With Atrial Fibrillation: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines and the Heart Rhythm Society Coronary Angiography after Cardiac Arrest without ST-Segment Elevation Large-Bore Radial Access for Complex PCI: A Flash of COLOR With Some Shades of Grey Novel functions of macrophages in the heart: insights into electrical conduction, stress, and diastolic dysfunction Thin Composite-Wire-Strut Zotarolimus-Eluting Stents Versus Ultrathin-Strut Sirolimus-Eluting Stents in BIONYX at 2 Years Major infections after bypass surgery and stenting for multivessel coronary disease in the randomised SYNTAX trial Post-Stroke Cardiovascular Complications and Neurogenic Cardiac Injury: JACC State-of-the-Art Review Association of Body Mass Index With Lifetime Risk of Cardiovascular Disease and Compression of Morbidity Heart Disease and Stroke Statistics-2019 Update: A Report From the American Heart Association

Clinical TrialVolume 13, Issue 1, January 2020

JOURNAL:JACC Cardiovasc Interv. Article Link

Randomized Comparison of Ridaforolimus-Eluting and Zotarolimus-Eluting Coronary Stents 2-Year Clinical Outcomes: From the BIONICS and NIREUS Trials

M Konigstein, PC Smits, MP Love et al. Keywords: PCI; DES; ridaforolimus vs. zotarolimus

ABSTRACT


OBJECTIVES - This study sought to determine clinical outcomes between treatment groups over long-term follow-up.

 

BACKGROUND - The safety and efficacy of a ridaforolimus-eluting stent (RES) was evaluated in the BIONICS (BioNIR Ridaforolimus-Eluting Coronary Stent System in Coronary Stenosis) and NIREUS (BioNIR Ridaforolimus Eluting Coronary Stent System [BioNIR] European Angiography Study) trials, demonstrating noninferiority of RES in comparison with a zotarolimus-eluting stent (ZES) regarding 1-year target lesion failure (TLF) and 6-month angiographic late lumen loss, respectively.

 

METHODS - Patient-level data from the BIONICS (N = 1,919) and NIREUS (N = 302) randomized trials were pooled, and outcomes in patients implanted with RES and ZES compared. Broad inclusion criteria allowed enrollment of patients with acute coronary syndromes and complex lesions. The primary endpoint was the 2-year rate of TLF or clinically driven target lesion revascularization.

 

RESULTS - A total of 2,221 patients (age 63.2 ± 10.3 years; 79.7% men) undergoing percutaneous coronary intervention with RES (n = 1,159) or ZES (n = 1,062) were included. Clinical and angiographic characteristics were similar between groups. At 2 years, the primary endpoint of TLF was similar among patients implanted with RES and ZES (7.0% vs. 7.2%; p = 0.94). Rates of target lesion revascularization (4.8% RES vs. 4.1% ZES; p = 0.41) and target vesselrelated myocardial infarction (3.1% RES vs. 3.8% ZES; p = 0.52) did not differ between groups. The overall rate of stent thrombosis was also similar (0.5% RES vs. 0.9% ZES; p = 0.39).

 

CONCLUSIONS -  In a pooled analysis of 2 randomized trials, 2-year clinical outcomes were similar between patients undergoing percutaneous coronary intervention with RES and ZES. These results support the long-term safety and efficacy of RES for the treatment of a broad population of patients with coronary artery disease.