Left Ventricular Assist Devices for Lifelong Support Incidence of contrast-induced acute kidney injury in a large cohort of all-comers undergoing percutaneous coronary intervention: Comparison of five contrast media Radionuclide Image-Guided Repair of the Heart 稳定性冠心病诊断与治疗指南 When high‐volume PCI operators in high‐volume hospitals move to lower volume hospitals—Do they still maintain high volume and quality of outcomes? 2013 ACC/AHA Guideline on the Treatment of Blood Cholesterol to Reduce Atherosclerotic Cardiovascular Risk in Adults: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines Coronary flow velocity reserve predicts adverse prognosis in women with angina and noobstructive coronary artery disease: resultsfrom the iPOWER study Percutaneous coronary intervention using a combination of robotics and telecommunications by an operator in a separate physical location from the patient: an early exploration into the feasibility of telestenting (the REMOTE-PCI study) Variation in Revascularization Practice and Outcomes in Asymptomatic Stable Ischemic Heart Disease 2017 ACC/AHA/AAPA/ABC/ACPM/AGS/APhA /ASH/ ASPC/NMA/PCNA Guideline for the Prevention, Detection, Evaluation, and Management of High Blood Pressure in Adults: Executive Summary : A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines

Clinical TrialVolume 13, Issue 1, January 2020

JOURNAL:JACC Cardiovasc Interv. Article Link

Randomized Comparison of Ridaforolimus-Eluting and Zotarolimus-Eluting Coronary Stents 2-Year Clinical Outcomes: From the BIONICS and NIREUS Trials

M Konigstein, PC Smits, MP Love et al. Keywords: PCI; DES; ridaforolimus vs. zotarolimus

ABSTRACT


OBJECTIVES - This study sought to determine clinical outcomes between treatment groups over long-term follow-up.

 

BACKGROUND - The safety and efficacy of a ridaforolimus-eluting stent (RES) was evaluated in the BIONICS (BioNIR Ridaforolimus-Eluting Coronary Stent System in Coronary Stenosis) and NIREUS (BioNIR Ridaforolimus Eluting Coronary Stent System [BioNIR] European Angiography Study) trials, demonstrating noninferiority of RES in comparison with a zotarolimus-eluting stent (ZES) regarding 1-year target lesion failure (TLF) and 6-month angiographic late lumen loss, respectively.

 

METHODS - Patient-level data from the BIONICS (N = 1,919) and NIREUS (N = 302) randomized trials were pooled, and outcomes in patients implanted with RES and ZES compared. Broad inclusion criteria allowed enrollment of patients with acute coronary syndromes and complex lesions. The primary endpoint was the 2-year rate of TLF or clinically driven target lesion revascularization.

 

RESULTS - A total of 2,221 patients (age 63.2 ± 10.3 years; 79.7% men) undergoing percutaneous coronary intervention with RES (n = 1,159) or ZES (n = 1,062) were included. Clinical and angiographic characteristics were similar between groups. At 2 years, the primary endpoint of TLF was similar among patients implanted with RES and ZES (7.0% vs. 7.2%; p = 0.94). Rates of target lesion revascularization (4.8% RES vs. 4.1% ZES; p = 0.41) and target vesselrelated myocardial infarction (3.1% RES vs. 3.8% ZES; p = 0.52) did not differ between groups. The overall rate of stent thrombosis was also similar (0.5% RES vs. 0.9% ZES; p = 0.39).

 

CONCLUSIONS -  In a pooled analysis of 2 randomized trials, 2-year clinical outcomes were similar between patients undergoing percutaneous coronary intervention with RES and ZES. These results support the long-term safety and efficacy of RES for the treatment of a broad population of patients with coronary artery disease.