Comparison of Heart Team vs Interventional Cardiologist Recommendations for the Treatment of Patients With Multivessel Coronary Artery Disease Position paper of the EACVI and EANM on artificial intelligence applications in multimodality cardiovascular imaging using SPECT/CT, PET/CT, and cardiac CT Efficacy and safety of rosuvastatin vs. atorvastatin in lowering LDL cholesterol : A meta-analysis of trials with East Asian populations Plaque progression assessed by a novel semi-automated quantitative plaque software on coronary computed tomography angiography between diabetes and non-diabetes patients: A propensity-score matching study State of the Art in Noninvasive Imaging of Ischemic Heart Disease and Coronary Microvascular Dysfunction in Women: Indications, Performance, and Limitations Invasive Coronary Physiology After Stent Implantation: Another Step Toward Precision Medicine Percutaneous Repair or Medical Treatment for Secondary Mitral Regurgitation Nonproportional Hazards for Time-to-Event Outcomes in Clinical Trials: JACC Review Topic of the Week Rare Genetic Variants Associated With Sudden Cardiac Death in Adults Prospective Elimination of Distal Coronary Sinus to Left Atrial Connection for Atrial Fibrillation Ablation (PRECAF) Randomized Controlled Trial

Clinical TrialMarch 2020 Vol 13, Issue 3

JOURNAL:Circulation. Article Link

Randomized Comparison of Everolimus- and Zotarolimus-Eluting Coronary Stents With Biolimus-Eluting Stents in All-Comer Patients

YJ Youn, J-W Lee, J Yoon et al.

ABSTRACT


BACKGROUND - There is limited data comparing the Xience everolimus-eluting stent (EES) and the Resolute zotarolimus-eluting stent (ZES) with the BioMatrix biolimus-eluting stent (BES).


METHODS - This open-label, randomized, noninferiority trial enrolled all-comer patients to be randomly treated with either BES, EES, or ZES in a 1:1:1 ratio in 15 centers across South Korea. The primary end point was a device-oriented composite outcome consisting of cardiac death, target-vessel myocardial infarction, and clinically indicated target lesion revascularization at 24 months. The BES was compared with the EES and the ZES by intention-to-treat analyses with a noninferiority margin of 3.8%, respectively.


RESULTS - Because of slow recruitment and low event rates, this trial was prematurely terminated after enrollment of 1935 (75%) of the intended 2580 patients. Of the 1911 patients randomized to either EES (n=638), BES (n=634), or ZES (n =639), the rate of device-oriented composite outcome was 3.6%, 2.2%, and 3.9%, respectively, at 24 months (BES versus EES: absolute risk difference 1.4% [upper limit of 1-sided 95% CI: 3.2%]; Pfor noninferiority <0.001; BES versus ZES: absolute risk difference 1.7% [upper limit of 1-sided 95% CI: 3.6%]; Pfor noninferiority <0.001).


CONCLUSIONS - The BES was noninferior to either the EES or the ZES in all-comer patients for device-oriented composite outcome at the 24-month follow-up. However, caution is advised regarding interpretation of these results due to the premature termination of this study.