Systematic Review for the 2018 AHA/ACC/AACVPR/AAPA/ABC/ACPM/ADA/AGS/APhA/ASPC/NLA/PCNA Guideline on the Management of Blood Cholesterol: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines Randomized Comparison Between Radial and Femoral Large-Bore Access for Complex Percutaneous Coronary Intervention Coronary Angiography after Cardiac Arrest without ST-Segment Elevation Association of Coronary Anatomical Complexity With Clinical Outcomes After Percutaneous or Surgical Revascularization in the Veterans Affairs Clinical Assessment Reporting and Tracking Program Basic Biology of Oxidative Stress and the Cardiovascular System: Part 1 of a 3-Part Series Discharge Against Medical Advice After Percutaneous Coronary Intervention in the United States Hemodynamic Response to Nitroprusside in Patients With Low-Gradient Severe Aortic Stenosis and Preserved Ejection Fraction The Prognostic Value of Exercise Echocardiography After Percutaneous Coronary Intervention Large-Bore Radial Access for Complex PCI: A Flash of COLOR With Some Shades of Grey European Bifurcation Club White Paper on Stenting Techniques for Patients With Bifurcated Coronary Artery Lesions

Review Article2017 Jun 13;69(23):2845-2861. ​

JOURNAL:J Am Coll Cardiol. Article Link

Left Ventricular Assist Devices for Lifelong Support

Pinney SP, Anyanwu AC, Lala A et al. Keywords: cardiothoracic surgery; heart failure; hemocompatibility

ABSTRACT


Continuous-flow left ventricular assist devices (LVADs) have revolutionized advanced heart failure care. These compact, fully implantable heart pumps are capable of providing meaningful increases in survival, functional capacity, and quality of life. Implantation volumes continue to grow, but several challenges remain to be overcome before LVADs will be considered as the therapy of choice for all patients with advanced heart failure. They must be able to consistently extend survival for the long term (7 to 10 years), rather than the midterm (3 to 5 years) more typical of contemporary devices; they must incorporate design elements that reduce shear stress and avoid stasis to reduce the frequent adverse events of bleeding, stroke, and pump thrombosis; and they must become more cost-effective. The advancements in engineering, implantation technique, and medical management detailed in this review will highlight the progress made toward achieving lifelong LVAD support and the challenges that remain.