Intravascular Ultrasound to Guide Left Main Stem Intervention: A Sub-Study of the NOBLE Trial Management of left main disease: an update Percutaneous Coronary Intervention vs Coronary Artery Bypass Grafting in Patients With Left Main Coronary Artery Stenosis: A Systematic Review and Meta-analysis Operator Experience and Outcomes After Left Main Percutaneous Coronary Intervention Differential prognostic impact of treatment strategy among patients with left main versus non-left main bifurcation lesions undergoing percutaneous coronary intervention: results from the COBIS (Coronary Bifurcation Stenting) Registry II Long-term results after PCI of unprotected distal left main coronary artery stenosis: the Bifurcations Bad Krozingen (BBK)-Left Main Registry Surgical ineligibility and mortality among patients with unprotected left main or multivessel coronary artery disease undergoing percutaneous coronary intervention Percutaneous Coronary Intervention Versus Coronary Artery Bypass Grafting in Patients With Left Main and Multivessel Coronary Artery Disease: Do We Have the Evidence? Two-year outcomes following unprotected left main stenting with first vs new-generation drug-eluting stents: the FINE registry. EuroIntervention. Randomized Trial of Stents Versus Bypass Surgery for Left Main Coronary Artery Disease: 5-Year Outcomes of the PRECOMBAT Study

Review Article18 July 2017, [Epub ahead of print]

JOURNAL:Lancet Article Link

2-year outcomes with the Absorb bioresorbable scaffold for treatment of coronary artery disease: a systematic review and meta-analysis of seven randomised trials with an individual patient data substudy

Z.A. Ali; P.W. Serruys; G.W. Stone et al Keywords: Absorb bioresorbable scaffold, individual patient

ABSTRACT


Background - Bioresorbable vascular scaffolds (BVS) offer the potential to improve long-term outcomes of percutaneous coronary intervention after their complete bioresorption. Randomised trials have shown non-inferiority between BVS and metallic drug-eluting stents at 1 year in composite safety and effectiveness outcomes, although some increases in rates of target vessel-related myocardial infarction and device thrombosis were identified. Outcomes of BVS following the first year after implantation are unknown. We sought to ascertain whether BVS are as safe and effective as drug-eluting stents within 2 years after implantation and between 1 and 2 years.


Methods - We did a systematic review and meta-analysis of randomised trials in which patients were randomly assigned to everolimus-eluting Absorb BVS or metallic everolimus-eluting stents (EES) and followed up for at least 2 years. We searched MEDLINE, the Cochrane database, TCTMD, ClinicalTrials.gov, Clinical Trial Results, CardioSource, and abstracts and presentations from major cardiovascular meetings up to April 1, 2017, to identify relevant studies. The primary efficacy outcome measure was the device-oriented composite endpoint (cardiac mortality, target vessel-related myocardial infarction, or ischaemia-driven target lesion revascularisation) and the primary safety outcome measure was definite or probable device thrombosis. Individual patient data from the four ABSORB trials were used for landmark and subgroup analysis and multivariable modelling.


Findings - We identified seven randomised trials in which 5583 patients were randomly assigned to Absorb BVS (n=3261) or metallic EES (n=2322) and followed up for 2 years. BVS had higher 2-year relative risks of the device-oriented composite endpoint than did EES (9.4% [304 of 3217] vs 7.4% [169 of 2299]; relative risk [RR] 1.29 [95% CI 1.08-1.56], p=0.0059). These differences were driven by increased rates of target vessel-related myocardial infarction (5.8% [187 of 3218] vs 3.2% [74 of 2299]; RR 1.68 [95% CI 1.29-2.19], p=0.0003) and ischaemia-driven target lesion revascularisation (5.3% [169 of 3217] vs 3.9% [90 of 2300]; 1.40 [1.09-1.80], p=0.0090) with BVS, with non-significant differences in cardiac mortality. The cumulative 2-year incidence of device thrombosis was higher with BVS than with EES (2.3% [73 of 3187] vs 0.7% [16 of 2281]; RR 3.35 [95% CI 1.96-5.72], p<0.0001). Landmark analysis between 1 and 2 years also showed higher rates of the device-oriented composite endpoint (3.3% [69 of 2100] vs 1.9% [23 of 1193]; RR 1.64 [95% CI 1.03-2.61], p=0.0376) and device thrombosis (0.5% [11 of 2085] vs none [0 of 1183], p<0.0001) in BVS-treated patients than in EES-treated patients.


Interpretation - BVS was associated with increased rates of composite device-oriented adverse events and device thrombosis cumulatively at 2 years and between 1 and 2 years of follow-up compared with EES.