CBS 2019
CBSMD教育中心
English

血管内超声指导

科研文章

荐读文献

Relationship between intravascular ultrasound guidance and clinical outcomes after drug-eluting stents: the assessment of dual antiplatelet therapy with drug-eluting stents (ADAPT-DES) study Assessment of coronary atherosclerosis by IVUS and IVUS-based imaging modalities: progression and regression studies, tissue composition and beyond Intravascular ultrasound-guided implantation of drug-eluting stents to improve outcome: a meta-analysis Clinical impact of intravascular ultrasound-guided chronic total occlusion intervention with zotarolimus-eluting versus biolimus-eluting stent implantation: randomized study Intravascular ultrasound guidance to minimize the use of iodine contrast in percutaneous coronary intervention: the MOZART (Minimizing cOntrast utiliZation With IVUS Guidance in coRonary angioplasTy) randomized controlled trial Role of Proximal Optimization Technique Guided by Intravascular Ultrasound on Stent Expansion, Stent Symmetry Index, and Side-Branch Hemodynamics in Patients With Coronary Bifurcation Lesions Outcomes with intravascular ultrasound-guided stent implantation: a meta-analysis of randomized trials in the era of drug-eluting stents Mechanical complications of everolimus-eluting stents associated with adverse events: an intravascular ultrasound study Consensus from the 5th European Bifurcation Club meeting Intravascular ultrasound predictors for edge restenosis after newer generation drug-eluting stent implantation

Original Research2012 Feb 15;109(4):455-60.

JOURNAL:Am J Cardiol. Article Link

Usefulness of minimum stent cross sectional area as a predictor of angiographic restenosis after primary percutaneous coronary intervention in acute myocardial infarction (from the HORIZONS-AMI Trial IVUS substudy)

Choi SY, Maehara A, Cristea E et al. Keywords: HORIZONS-AMI trial; STEMI; angiographic restenosis; PPCI; minimum stent cross sectional area

ABSTRACT

 

HORIZONS-AMI was a prospective dual-arm randomized trial of different antithrombotic regimens and stent types in patients with ST-segment elevation myocardial infarction. A formal intravascular ultrasound (IVUS) substudy enrolled 464 patients with baseline and 13-month follow-up at 36 centers. Of them, 318 patients with 355 lesions were evaluated for this study. Angiographic restenosis occurred in 45 of 355 lesions (12.7%). Bare-metal stent use (45.5% vs 21.2%, p <0.001) and diabetes mellitus (29.5% vs 10.9%, p <0.001) were more prevalent in patients with versus without restenosis. Postprocedure IVUS minimum lumen area (5.6 mm2, 5.0 to 6.1, vs 6.7 mm2, 6.5 to 6.9, p <0.001), minimum stent area (5.7 mm2, 5.1 to 6.3, vs 6.9 mm2, 6.6 to 7.1, p <0.001), and reference average lumen area (7.7 mm2, 6.8 to 8.6, vs 9.7 mm2, 9.3 to 10.1, p <0.001) were smaller in restenotic versus nonrestenotic lesions. By multivariable analysis, minimum stent area was an independent predictor of angiographic restenosis (odds ratio 0.75, 95% confidence interval 0.61 to 0.93, p = 0.009) in addition to diabetes, bare-metal stent use, and longer stent length. Attenuated plaque behind the stent struts had a trend to predict less binary restenosis (p = 0.07). In conclusion, a smaller IVUS minimum stent area was an independent predictor of angiographic restenosis after primary percutaneous intervention in patients with ST-segment elevation myocardial infarction, similar to patients with stable coronary artery disease.