Prognostic impact of baseline glucose levels in acute myocardial infarction complicated by cardiogenic shock-a substudy of the IABP-SHOCK II-trial Decade-Long Trends (2001 to 2011) in the Use of Evidence-Based Medical Therapies at the Time of Hospital Discharge for Patients Surviving Acute Myocardial Remote ischaemic conditioning and healthcare system delay in patients with ST-segment elevation myocardial infarction Analysis of reperfusion time trends in patients with ST-elevation myocardial infarction across New York State from 2004 to 2012 Effect of Plaque Burden and Morphology on Myocardial Blood Flow and Fractional Flow Reserve Prognostic significance of QRS fragmentation and correlation with infarct size in patients with anterior ST-segment elevation myocardial infarction treated with percutaneous coronary intervention: Insights from the INFUSE-AMI trial Door-to-balloon time and mortality among patients undergoing primary PCI Trends in early aspirin use among patients with acute myocardial infarction in China, 2001-2011: the China PEACE-Retrospective AMI study The China Patient-centered Evaluative Assessment of Cardiac Events (PEACE) Prospective Study of Percutaneous Coronary Intervention: Study Design Non-eligibility for reperfusion therapy in patients presenting with ST-segment elevation myocardial infarction: Contemporary insights from the National Cardiovascular Data Registry (NCDR)

Clinical Trial2018 Aug 27;11(16):1559-1571.

JOURNAL:JACC Cardiovasc Interv. Article Link

Long-Term Coronary Functional Assessment of the Infarct-Related Artery Treated With Everolimus-Eluting Bioresorbable Scaffolds or Everolimus-Eluting Metallic Stents: Insights of the TROFI II Trial

Gomez-Lara J, Brugaletta S, Ortega-Paz L et al. Keywords: ST-segment elevation myocardial infarction; bioresorbable vascular scaffolds; drug-eluting stent(s); endothelial dysfunction; optical coherence tomography

ABSTRACT


OBJECTIVES - The study sought to compare the vasomotor and microcirculatory function of the infarct-related artery (IRA) between bioresorbable vascular scaffolds (BVS) and everolimus-eluting stents (EES) at 3 years.


BACKGROUND - The ABSORB STEMI TROFI II study showed similar outcomes between BVS and EES in the context of ST-segment elevation myocardial infarction at 3 years.

METHODS - Sixty-three consecutive event-free patients of the randomized TROFI II study were screened to undergo coronary angiography with vasomotor, microcirculatory, and optical coherence tomography (OCT) examination at 3 years. Vasomotion was defined as >4% change in mean lumen diameter to acetylcholine (ACH) and nitroglycerin as assessed by quantitative angiography. Microcirculatory examination was performed with pressure or thermodilution techniques.

RESULTS - A total of 38 patients (20 BVS and 18 EES) were included. At 3 years, ≥60% of patients exhibited paradoxical vasoconstriction to ACH in the periscaffold or stent segments. Vasoconstriction to ACH and vasodilatation to nitroglycerin were more often observed in the scaffold or stent segment with BVS than with EES (77.8% vs. 25.0%; p = 0.008 and 61.1% vs. 18.8%; p = 0.018). The IRA-depending microcirculation showed similar index of resistance (23.8 vs. 22.4; p = 0.781), coronary flow reserve (2.4 vs. 1.9; p = 0.523), fractional flow reserve (0.91 vs. 0.93; p = 0.317), and absolute flow (135.5 ml/min vs. 147.3 ml/min; p = 0.791). OCT showed remaining strut footprints and larger number of intraluminal scaffold dismantling (26.3% vs. 0%; p = 0.049) in the BVS group.

CONCLUSIONS - Both endothelium-dependent and -independent vasomotion of the IRA were more evident with BVS, as compared with EES, at 3 years. Functional microcirculatory parameters were mostly adequate and similar between BVS and EES. Clinical implications of these findings warrant further investigations.

Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.