CBS 2019
CBSMD教育中心
English

经导管主动脉瓣置换

科研文章

荐读文献

Transcatheter Aortic-Valve Replacement with a Self-Expanding Valve in Low-Risk Patients Transcatheter Aortic-Valve Replacement with a Balloon-Expandable Valve in Low-Risk Patients Early Versus Standard Discharge After Transcatheter Aortic Valve Replacement: A Systematic Review and Meta-Analysis Surgical or Transcatheter Aortic-Valve Replacement in Intermediate-Risk Patients Preventing Coronary Obstruction During Transcatheter Aortic Valve Replacement From Computed Tomography to BASILICA Transcatheter or Surgical Aortic-Valve Replacement in Intermediate-Risk Patients A prospective, randomised trial of transapical transcatheter aortic valve implantation vs. surgical aortic valve replacement in operable elderly patients with aortic stenosis: the STACCATO trial Transcatheter Laceration of Aortic Leaflets to Prevent Coronary Obstruction During Transcatheter Aortic Valve Replacement: Concept to First-in-Human Transcatheter Versus Surgical Aortic Valve Replacement in Patients With Severe Aortic Valve Stenosis: 1-Year Results From the All-Comers NOTION Randomized Clinical Trial Comparative Accuracy of Focused Cardiac Ultrasonography and Clinical Examination for Left Ventricular Dysfunction and Valvular Heart Disease: A Systematic Review and Meta-analysis

Original ResearchVolume 13, Issue 6, March 2020

JOURNAL:JACC Cardiovasc Interv. Article Link

Coronary Protection to Prevent Coronary Obstruction During TAVR: A Multicenter International Registry

T Palmerini, T Chakravarty, F Saia et al. Keywords: coronary obstruction; stent thrombosis; TAVR

ABSTRACT


OBJECTIVES - The aim of this study was to investigate the safety and efficacy of coronary protection by preventive coronary wiring and stenting across the coronary ostia in patients at high risk for coronary obstruction after transcatheter aortic valve replacement (TAVR).

 

BACKGROUND - Coronary obstruction following TAVR is a life-threatening complication with high procedural and short-term mortality.

 

METHODS - Data were collected retrospectively from a multicenter international registry between April 2011 and February 2019.

 

RESULTS - Among 236 patients undergoing coronary protection with preventive coronary wiring, 143 had eventually stents implanted across the coronary ostia after valve deployment. At 3-year follow-up, rates of cardiac death were 7.8% in patients receiving stents and 15.7% in those not receiving stents (adjusted hazard ratio: 0.42; 95% confidence interval: 0.14 to 1.28; p = 0.13). There were 2 definite stent thromboses (0.9%) in patients receiving stents, both occurring after TAVR in “valve-in-valve” procedures. In patients not receiving stents, there were 4 delayed coronary occlusions (DCOs) (4.3%), occurring from 5 min to 6 h after wire removal. Three cases occurred in valve-in-valve procedures and 1 in a native aortic valve procedure. Distance between the virtual transcatheter valve and the protected coronary ostia <4 mm was present in 75.0% of patients with DCO compared with 30.4% of patients without DCO (p = 0.19).

 

CONCLUSIONS - In patients undergoing TAVR at high risk for coronary obstruction, preventive stent implantation across the coronary ostia is associated with good mid-term survival rates and low rates of stent thrombosis. Patients undergoing coronary protection with wire only have a considerable risk for DCO.