CBS 2019
CBSMD教育中心
中 文

推荐文献

Abstract

Recommended Article

Coronary Artery Calcium Is Associated with Left Ventricular Diastolic Function Independent of Myocardial Ischemia When high‐volume PCI operators in high‐volume hospitals move to lower volume hospitals—Do they still maintain high volume and quality of outcomes? ACCF/SCAI/STS/AATS/AHA/ASNC 2009 Appropriateness Criteria for Coronary Revascularization: A Report by the American College of Cardiology Foundation Appropriateness Criteria Task Force, Society for Cardiovascular Angiography and Interventions, Society of Thoracic Surgeons, American Association for Thoracic Surgery, American Heart Association, and the American Society of Nuclear Cardiology Endorsed by the American Society of Echocardiography, the Heart Failure Society of America, and the Society of Cardiovascular Computed Tomography Radionuclide Image-Guided Repair of the Heart 稳定性冠心病诊断与治疗指南 Incidence of contrast-induced acute kidney injury in a large cohort of all-comers undergoing percutaneous coronary intervention: Comparison of five contrast media Management of Patients With NSTE-ACS: A Comparison of the Recent AHA/ACC and ESC Guidelines Non-invasive detection of coronary inflammation using computed tomography and prediction of residual cardiovascular risk (the CRISP CT study): a post-hoc analysis of prospective outcome data

Review Article2017 Jun 13;69(23):2845-2861. ​

JOURNAL:J Am Coll Cardiol. Article Link

Left Ventricular Assist Devices for Lifelong Support

Pinney SP, Anyanwu AC, Lala A et al. Keywords: cardiothoracic surgery; heart failure; hemocompatibility

ABSTRACT


Continuous-flow left ventricular assist devices (LVADs) have revolutionized advanced heart failure care. These compact, fully implantable heart pumps are capable of providing meaningful increases in survival, functional capacity, and quality of life. Implantation volumes continue to grow, but several challenges remain to be overcome before LVADs will be considered as the therapy of choice for all patients with advanced heart failure. They must be able to consistently extend survival for the long term (7 to 10 years), rather than the midterm (3 to 5 years) more typical of contemporary devices; they must incorporate design elements that reduce shear stress and avoid stasis to reduce the frequent adverse events of bleeding, stroke, and pump thrombosis; and they must become more cost-effective. The advancements in engineering, implantation technique, and medical management detailed in this review will highlight the progress made toward achieving lifelong LVAD support and the challenges that remain.