CBS 2019
CBSMD教育中心
中 文

IVUS Guidance

Abstract

Recommended Article

Relation between baseline plaque features and subsequent coronary artery remodeling determined by optical coherence tomography and intravascular ultrasound Optical Frequency Domain Imaging Versus Intravascular Ultrasound in Percutaneous Coronary Intervention (OPINION Trial) Results From the OPINION Imaging Study A Combined Optical Coherence Tomography and Intravascular Ultrasound Study on Plaque Rupture, Plaque Erosion, and Calcified Nodule in Patients With ST-Segment Elevation Myocardial Infarction: Incidence, Morphologic Characteristics, and Outcomes After Percutaneous Coronary Intervention Coronary plaque redistribution after stent implantation is determined by lipid composition: A NIRS-IVUS analysis Successful Treatment of Unprotected Left Main Coronary Bifurcation Lesion Using Minimum Contrast Volume with Intravascular Ultrasound Guidance Intravascular Ultrasound and Angioscopy Assessment of Coronary Plaque Components in Chronic Totally Occluded Lesions Intravascular Ultrasound Assessment of In-Stent Restenosis in Saphenous Vein Grafts Catastrophic catheter-induced coronary artery vasospasm successfully rescued using intravascular ultrasound imaging guidance

Review Article2013 Dec 5;170(1):54-63.

JOURNAL:Int J Cardiol. Article Link

Use of IVUS guided coronary stenting with drug eluting stent: a systematic review and meta-analysis of randomized controlled clinical trials and high quality observational studies

Klersy C, Ferlini M, Raisaro A et al. Keywords: IVUS guidance; DES implantation; MACE, mortality; MI

ABSTRACT


BACKGROUND/OBJECTIVES - Long term safety of DES, particularly regarding thrombosis is of concern. The hypothesized underlying mechanisms (stent under expansion, malapposition) could be prevented by IVUS guidance. Aim of this meta-analysis of randomized controlled clinical trials (RCT) and high quality observational cohort studies (HQ-OBS) is to quantify the potential clinical benefit of intravascular ultrasound (IVUS) guidance in drug-eluting stents (DES) implantation.


METHODS - We performed an extensive literature search for full-text articles published in 2003–2013. The primary outcome was the rate of major adverse cardiac events (MACE) in RCT and HQ-OBS; secondary outcomes were death, myocardial infarction (MI), revascularization, thrombosis and post-procedural minimum lumen diameter (MLD). Fixed/random effect relative risks (RRs) or standardized mean difference (SMD) and 95% confidence interval (95% CI) were computed for the meta-analysis.


RESULTS - Thirty-four articles were retrieved from 268 found; of these 3 were RCT and 9 were HQ-OBS; 18,707 patients were enrolled, 1037 in RCT and 17,670 in OBS. Median follow-up was 20 months. IVUS guidance was associated with a significantly lower rate of MACE (RR=0.80, 95% CI 0.71–0.89, p b 0.001), death (RR=0.60, 95% CI 0.48–0.74, p b 0.001), MI (RR=0.59, 95% CI 0.44–0.80, p=0.001) and thrombosis (RR=0.50, 95% CI 0.32–0.80, p=0.007) and larger MLD (SMD=0.15, 95% CI 0.03 to 0.27, p=0.014), but not of revascularization (RR=0.95, 95% CI 0.82–1.09, p=0.75).


CONCLUSIONS - In this meta-analysis, IVUS guidance in DES implantation appears to reduce MACE, mortality and MI, possibly by reducing thrombosis rather than restenosis rate. Patients at high risk for thrombosis might be identified as the best candidate for IVUS guidance.