Intravascular ultrasound guidance of percutaneous coronary intervention in ostial chronic total occlusions: a description of the technique and procedural results Combined use of OCT and IVUS in spontaneous coronary artery dissection The outcomes of intravascular ultrasound-guided drug-eluting stent implantation among patients with complex coronary lesions: a comprehensive meta-analysis of 15 clinical trials and 8,084 patients Increased glycated albumin and decreased esRAGE levels in serum are related to negative coronary artery remodeling in patients with type 2 diabetes: an Intravascular ultrasound study Serial intravascular ultrasound assessment of very late stent thrombosis after sirolimus-eluting stent placement Impact of Positive and Negative Lesion Site Remodeling on Clinical Outcomes : Insights From PROSPECT Impact of Intravascular Ultrasound-Guided Drug-Eluting Stent Implantation on Patients With Chronic Kidney Disease: Subgroup Analysis From ULTIMATE Trial Novel predictors of late lumen enlargement in distal reference segments after successful recanalization of coronary chronic total occlusion

Original Research2013 Mar 15;111(6):829-35.

JOURNAL:Am J Cardiol. Article Link

Differential prognostic effect of intravascular ultrasound use according to implanted stent length

Ahn JM, Han S, Park YK et al. Keywords: IVUS guided PCI; DES; outcome; stent length

ABSTRACT


It is unknown whether the use of intravascular ultrasound (IVUS) guidance during percutaneous coronary intervention can attenuate the stent length effect on clinical outcomes. The aim of the present study was to determine the differential prognostic effect of IVUS according to the implanted stent length. We enrolled 3,244 consecutive patients from the Interventional Cardiology Research In-cooperation Society-Drug-Eluting Stents (IRIS-DES) registry who had undergone single or overlapping stent implantation. The primary end point was major adverse cardiac events (MACE; a composite of death, myocardial infarction, and target vessel revascularization). The study population was divided by the tertiles of implanted stent length and IVUS usage. IVUS use was at the discretion of the operator. After adjusting for significant covariates, the stent length was significantly associated with the risk of MACE in the no-IVUS group (hazard ratio 1.13, 95% confidence interval 1.01 to 1.28, p = 0.042) but not in the IVUS group (hazard ratio 1.08, 95% confidence interval 0.97 to 1.20, p = 0.16). In addition, in patients with an implanted stent length of ≤22 mm (n = 998), the risk of MACE was not significantly different between the IVUS group and the no-IVUS group (hazard ratio 1.06, 95% confidence interval 0.50 to 2.28, p = 0.88). In contrast, in patients with a longer implanted stent length, the risk of MACE was significantly lower in the IVUS group than in the no-IVUS group (hazard ratio 0.47, 95% confidence interval 0.24 to 0.92, p = 0.027 for 23 to 32 mm, n = 1,109; hazard ratio 0.57, 95% confidence interval 0.33 to 0.98, p = 0.042 for ≥33 mm, n = 1,137). In conclusion, IVUS usage can attenuate the detrimental effect of the increase in the implanted stent length, supporting IVUS usage, particularly during percutaneous coronary intervention with long stent implantation.