CBS 2019
CBSMD教育中心
中 文

IVUS Guidance

Abstract

Recommended Article

Positive remodeling at 3 year follow up is associated with plaque-free coronary wall segment at baseline: a serial IVUS study Clinical use of intracoronary imaging. Part 1: guidance and optimization of coronary interventions. An expert consensus document of the European Association of Percutaneous Cardiovascular Interventions: Endorsed by the Chinese Society of Cardiology Clinical Outcomes Following Intravascular Imaging-Guided Versus Coronary Angiography-Guided Percutaneous Coronary Intervention With Stent Implantation: A Systematic Review and Bayesian Network Meta-Analysis of 31 Studies and 17,882 Patients Long-term health outcome and mortality evaluation after invasive coronary treatment using drug eluting stents with or without the IVUS guidance. Randomized control trial. HOME DES IVUS Optical frequency domain imaging vs. intravascular ultrasound in percutaneous coronary intervention (OPINION trial): one-year angiographic and clinical results Role of Proximal Optimization Technique Guided by Intravascular Ultrasound on Stent Expansion, Stent Symmetry Index, and Side-Branch Hemodynamics in Patients With Coronary Bifurcation Lesions Subclinical Atherosclerosis Burden by 3D Ultrasound in Mid-Life: The PESA Study Meta-analysis of outcomes after intravascular ultrasound-guided versus angiography-guided drug-eluting stent implantation in 26,503 patients enrolled in three randomized trials and 14 observational studies

Original Research2013 Mar 15;111(6):829-35.

JOURNAL:Am J Cardiol. Article Link

Differential prognostic effect of intravascular ultrasound use according to implanted stent length

Ahn JM, Han S, Park YK et al. Keywords: IVUS guided PCI; DES; outcome; stent length

ABSTRACT


It is unknown whether the use of intravascular ultrasound (IVUS) guidance during percutaneous coronary intervention can attenuate the stent length effect on clinical outcomes. The aim of the present study was to determine the differential prognostic effect of IVUS according to the implanted stent length. We enrolled 3,244 consecutive patients from the Interventional Cardiology Research In-cooperation Society-Drug-Eluting Stents (IRIS-DES) registry who had undergone single or overlapping stent implantation. The primary end point was major adverse cardiac events (MACE; a composite of death, myocardial infarction, and target vessel revascularization). The study population was divided by the tertiles of implanted stent length and IVUS usage. IVUS use was at the discretion of the operator. After adjusting for significant covariates, the stent length was significantly associated with the risk of MACE in the no-IVUS group (hazard ratio 1.13, 95% confidence interval 1.01 to 1.28, p = 0.042) but not in the IVUS group (hazard ratio 1.08, 95% confidence interval 0.97 to 1.20, p = 0.16). In addition, in patients with an implanted stent length of ≤22 mm (n = 998), the risk of MACE was not significantly different between the IVUS group and the no-IVUS group (hazard ratio 1.06, 95% confidence interval 0.50 to 2.28, p = 0.88). In contrast, in patients with a longer implanted stent length, the risk of MACE was significantly lower in the IVUS group than in the no-IVUS group (hazard ratio 0.47, 95% confidence interval 0.24 to 0.92, p = 0.027 for 23 to 32 mm, n = 1,109; hazard ratio 0.57, 95% confidence interval 0.33 to 0.98, p = 0.042 for ≥33 mm, n = 1,137). In conclusion, IVUS usage can attenuate the detrimental effect of the increase in the implanted stent length, supporting IVUS usage, particularly during percutaneous coronary intervention with long stent implantation.