Clinical Outcomes Following Intravascular Imaging-Guided Versus Coronary Angiography–Guided Percutaneous Coronary Intervention With Stent Implantation: A Systematic Review and Bayesian Network Meta-Analysis of 31 Studies and 17,882 Patients Intravascular ultrasound-guided drug-eluting stent implantation is associated with improved clinical outcomes in patients with unstable angina and complex coronary artery true bifurcation lesions Prognostic Value of Intravascular Ultrasound in Patients With Coronary Artery Disease Intraluminal Intensity of Blood Speckle on Intravascular Ultrasound, a Novel Predictor of Periprocedural Myocardial Injury After Coronary Stenting Serial intravascular ultrasound analysis of the main and side branches in bifurcation lesions treated with the T-stenting technique In Vivo Calcium Detection by Comparing Optical Coherence Tomography, Intravascular Ultrasound, and Angiography Optical coherence tomography and intravascular ultrasound assessment of the anatomic size and wall thickness of a muscle bridge segment Comparison of plaque characteristics in narrowings with ST-elevation myocardial infarction (STEMI), non-STEMI/unstable angina pectoris and stable coronary artery disease (from the ADAPT-DES IVUS Substudy)

Original Research2018 Sep;34(9):1365-1371.

JOURNAL:Int J Cardiovasc Imaging. Article Link

Intravascular ultrasound assessment of the effects of rotational atherectomy in calcified coronary artery lesions

Kim SS, Yamamoto MH, Maehara A et al. Keywords: Calcified lesions; Intravascular ultrasound; Rotational atherectomy

ABSTRACT


We sought to clarify intravascular ultrasound (IVUS) features of rotational atherectomy (RA) of calcified lesions. IVUS was performed post-RA and post-stent in 38 lesions and analyzed every 1 mm. Pre-intervention IVUS was performed when the IVUS catheter crossed the lesion (n = 11). Calcium Index was average calcium angle multiplied by calcium length. We compared lowest (n = 13), middle (n = 13), and highest (n = 12) Calcium Index tertiles. Reverberations (multiple reflections from calcium) with a concave-shaped lumen in the post-RA IVUS were considered to represent RA-related calcium modification. Newly visible perivascular tissue through a previously solid arc of calcium in the post-stent IVUS was also evaluated. Comparing the pre and post-RA IVUS, maximum reverberation angle, and length increased significantly after RA (angle, from 45° [31, 67] to 96° [50, 148], p = 0.003; length, from 4.0 mm [2.0, 6.0] to 8.0 mm [4.0, 14.0], p = 0.005). In the post-RA IVUS, reverberations had a larger angle in the middle and highest Calcium Index tertiles (lowest, 91° [64, 133]; middle, 135° [107, 201]; highest, 150° [93, 208], p = 0.03). Post-stent newly visible perivascular tissue was more frequent in the middle and highest Calcium Index tertiles (lowest, 30.8%; middle, 69.2%; highest, 75.0%, p = 0.049). Minimum stent area was similar after calcium modification by RA irrespective of the severity of the Calcium Index (lowest, 6.7 mm2 [5.7, 8.9]; middle, 5.6 mm2 [4.9, 6.8]; highest, 6.7 mm2 [5.9, 8.2], p = 0.2). Greater calcium modification by RA occurs in severely calcified lesions with smaller lumen diameters to mitigate against stent underexpansion.