CBS 2019
CBSMD教育中心
中 文

IVUS Guidance

Abstract

Recommended Article

Relation between baseline plaque features and subsequent coronary artery remodeling determined by optical coherence tomography and intravascular ultrasound Optical Frequency Domain Imaging Versus Intravascular Ultrasound in Percutaneous Coronary Intervention (OPINION Trial) Results From the OPINION Imaging Study A Combined Optical Coherence Tomography and Intravascular Ultrasound Study on Plaque Rupture, Plaque Erosion, and Calcified Nodule in Patients With ST-Segment Elevation Myocardial Infarction: Incidence, Morphologic Characteristics, and Outcomes After Percutaneous Coronary Intervention Coronary plaque redistribution after stent implantation is determined by lipid composition: A NIRS-IVUS analysis Successful Treatment of Unprotected Left Main Coronary Bifurcation Lesion Using Minimum Contrast Volume with Intravascular Ultrasound Guidance Intravascular Ultrasound and Angioscopy Assessment of Coronary Plaque Components in Chronic Totally Occluded Lesions Catastrophic catheter-induced coronary artery vasospasm successfully rescued using intravascular ultrasound imaging guidance Intravascular Ultrasound Assessment of In-Stent Restenosis in Saphenous Vein Grafts

Clinical TrialOctober 2020

JOURNAL:JACC Article Link

Percutaneous Coronary Intervention for Vulnerable Coronary Atherosclerotic Plaque

GW. Stone, A Maehara, and for the PROSPECT ABSORB Investigators. Keywords: vulnerable plaque; prognosis; stent; bioresorbable scaffold

ABSTRACT

BACKGROUND - Acute coronary syndromes most commonly arise from thrombosis of lipid-rich coronary atheromas that have large plaque burden despite angiographically appearing mild.


OBJECTIVES - We sought to examine the outcomes of percutaneous coronary intervention (PCI) of non-flow-limiting vulnerable plaques.


METHODS - Three-vessel imaging was performed with a combination intravascular ultrasound (IVUS) and near-infrared spectroscopy (NIRS) catheter after successful PCI of all flow-limiting coronary lesions in 898 patients presenting with myocardial infarction (MI). Patients with an angiographically non-obstructive stenosis not intended for PCI but with IVUS plaque burden ≥65% were randomized to treatment of the lesion with a bioresorbable vascular scaffold (BVS) plus guideline-directed medical therapy (GDMT) vs. GDMT alone. The primary powered effectiveness endpoint was the IVUS-derived minimum lumen area (MLA) at protocol-driven 25-month follow-up. The primary (non-powered) safety endpoint was randomized target lesion failure (TLF; cardiac death, target vessel-related MI or clinically-driven target lesion revascularization) at 24 months. The secondary (non-powered) clinical effectiveness endpoint was randomized lesion-related major adverse cardiac events (MACE; cardiac death, MI, unstable angina, or progressive angina) at latest follow-up.


RESULTS - A total of 182 patients were randomized (93 BVS, 89 GDMT alone) at 15 centers. The median angiographic diameter stenosis of the randomized lesions was 41.6%; by NIRS-IVUS median plaque burden was 73.7%, median MLA was 2.9 mm2, and median maximum lipid plaque content was 33.4%. Angiographic follow-up at 25 months was completed in 167 patients (91.8%), and median clinical follow-up was 4.1 years. The follow-up MLA in BVS-treated lesions was 6.9±2.6 mm2 compared with 3.0±1.0 mm2 in GDMT alone-treated lesions (least square means difference 3.9 mm2, 95% CI 3.3-4.5, P<0.0001). TLF at 24 months occurred in similar rates of BVS-treated and GDMT alone-treated patients (4.3% vs. 4.5%; P=0.96). Randomized lesion-related MACE occurred in 4.3% BVS-treated patients vs. 10.7% GDMT alone-treated patients (OR 0.38, 95% CI 0.11-1.28, P=0.12).


CONCLUSIONS - PCI of angiographically mild lesions with large plaque burden was safe, substantially enlarged the follow-up MLA and was associated with favorable long-term clinical outcomes, warranting the performance of an adequately powered randomized trial.