CBS 2019
CBSMD教育中心
中 文

光学相关断层扫描

Abstract

Recommended Article

Histopathological validation of optical coherence tomography findings of the coronary arteries Nonculprit Lesion Plaque Morphology in Patients With ST-Segment–Elevation Myocardial Infarction: Results From the COMPLETE Trial Optical Coherence Tomography Substudys Neoatherosclerosis in Patients With Coronary Stent Thrombosis: Findings From Optical Coherence Tomography Imaging (A Report of the PRESTIGE Consortium) Impact of low tissue backscattering by optical coherence tomography on endothelial function after drug-eluting stent implantation Coronary Artery Intraplaque Microvessels by Optical Coherence Tomography Correlate With Vulnerable Plaque and Predict Clinical Outcomes in Patients With Ischemic Angina Spontaneous Coronary Artery Dissection: Pathophysiological Insights From Optical Coherence Tomography Angiography Alone Versus Angiography Plus Optical Coherence Tomography to Guide Percutaneous Coronary Intervention: Outcomes From the Pan-London PCI Cohort Comparison of Coronary Intimal Plaques by Optical Coherence Tomography in Arteries With Versus Without Internal Running Vasa Vasorum

Original Research2019 Mar 27. [Epub ahead of print]

JOURNAL:Catheter Cardiovasc Interv. Article Link

Characteristics of abnormal post-stent optical coherence tomography findings in hemodialysis patients

Matsuhiro Y, Matsunaga-Lee Y, Nakamura D et al. Keywords: chronic renal disease; coronary artery disease; OCT; stents

ABSTRACT


AIM - Clinical outcomes after percutaneous coronary intervention (PCI) in hemodialysis (HD) patients are significantly worse than those in non-HD patients. Optical coherence tomography (OCT) is a high resolution imaging modality and provides a detailed assessment of post-interventional abnormal findings that influence worse clinical outcomes. However, little is known about the abnormal post-stent OCT findings in HD patients. Therefore, in this study, we compared the abnormal post-stent OCT findings between HD and non-HD patients.


METHODS - One hundred thirty-nine consecutive OCT guided PCI (21 lesions in HD patients and 118 lesions in non-HD patients) were enrolled. We compared the post-stent OCT findings, including the edge dissections, under expansion index (minimum stent area/mean reference area), and stent eccentricity index (minimum stent diameter/maximum stent diameter) between HD and non-HD patients. We also compared the device-oriented clinical events (DoCEs) at 8 months of follow up.


RESULTS - There was a significantly higher prevalence of distal edge dissections (16.7% vs. 2.8%, P = 0.011) in HD patients. HD patients had a significantly lower under expansion index (0.76 ± 0.21 vs. 0.85 ± 0.14, P = 0.029) and stent eccentricity index (0.82 ± 0.09 vs. 0.88 ± 0.18, P = 0.018). The cumulative rate of DoCEs was significantly higher in the HD patients (23.8% vs. 5.2%, P = 0.013).


CONCLUSIONS - A higher prevalence of distal edge dissections, under expansion and stent eccentricity were detected by the detailed OCT findings in HD patients.

 

© 2019 Wiley Periodicals, Inc.