Joint consensus on the use of OCT in coronary bifurcation lesions by the European and Japanese bifurcation clubs Changes in Coronary Plaque Composition in Patients With Acute Myocardial Infarction Treated With High-Intensity Statin Therapy (IBIS-4): A Serial Optical Coherence Tomography Study Randomized Comparison Between Everolimus-Eluting Bioresorbable Scaffold and Metallic Stent: Multimodality Imaging Through 3 Years Optical Coherence Tomography–Defined Plaque Vulnerability in Relation to Functional Stenosis Severity and Microvascular Dysfunction Pancoronary Plaque Characteristics in STEMI Caused by Culprit Plaque Erosion Versus Rupture: 3-Vessel OCT Study Drug-eluting stent implantation in patients with acute coronary syndrome - the Activity of Platelets after Inhibition and Cardiovascular Events: Optical Coherence Tomography (APICE OCT) study Coronary Optical Coherence Tomography and Cardiac Magnetic Resonance Imaging to Determine Underlying Causes of Myocardial Infarction With Nonobstructive Coronary Arteries in Women Characteristics of stent thrombosis in bifurcation lesions analysed by optical coherence tomography

Original Research2019 Mar 27. [Epub ahead of print]

JOURNAL:Catheter Cardiovasc Interv. Article Link

Characteristics of abnormal post-stent optical coherence tomography findings in hemodialysis patients

Matsuhiro Y, Matsunaga-Lee Y, Nakamura D et al. Keywords: chronic renal disease; coronary artery disease; OCT; stents

ABSTRACT


AIM - Clinical outcomes after percutaneous coronary intervention (PCI) in hemodialysis (HD) patients are significantly worse than those in non-HD patients. Optical coherence tomography (OCT) is a high resolution imaging modality and provides a detailed assessment of post-interventional abnormal findings that influence worse clinical outcomes. However, little is known about the abnormal post-stent OCT findings in HD patients. Therefore, in this study, we compared the abnormal post-stent OCT findings between HD and non-HD patients.


METHODS - One hundred thirty-nine consecutive OCT guided PCI (21 lesions in HD patients and 118 lesions in non-HD patients) were enrolled. We compared the post-stent OCT findings, including the edge dissections, under expansion index (minimum stent area/mean reference area), and stent eccentricity index (minimum stent diameter/maximum stent diameter) between HD and non-HD patients. We also compared the device-oriented clinical events (DoCEs) at 8 months of follow up.


RESULTS - There was a significantly higher prevalence of distal edge dissections (16.7% vs. 2.8%, P = 0.011) in HD patients. HD patients had a significantly lower under expansion index (0.76 ± 0.21 vs. 0.85 ± 0.14, P = 0.029) and stent eccentricity index (0.82 ± 0.09 vs. 0.88 ± 0.18, P = 0.018). The cumulative rate of DoCEs was significantly higher in the HD patients (23.8% vs. 5.2%, P = 0.013).


CONCLUSIONS - A higher prevalence of distal edge dissections, under expansion and stent eccentricity were detected by the detailed OCT findings in HD patients.

 