CBS 2019
CBSMD教育中心
English

血管内超声指导

科研文章

荐读文献

Impact of Intravascular Ultrasound-Guided Drug-Eluting Stent Implantation on Patients With Chronic Kidney Disease: Subgroup Analysis From ULTIMATE Trial Effects of Intravascular Ultrasound-Guided Versus Angiography-Guided New-Generation Drug-Eluting Stent Implantation: Meta-Analysis With Individual Patient-Level Data From 2,345 Randomized Patients Serial intravascular ultrasound assessment of very late stent thrombosis after sirolimus-eluting stent placement Usefulness of minimum stent cross sectional area as a predictor of angiographic restenosis after primary percutaneous coronary intervention in acute myocardial infarction (from the HORIZONS-AMI Trial IVUS substudy) Coronary artery imaging with intravascular high-frequency ultrasound Randomized comparison of clinical outcomes between intravascular ultrasound and angiography-guided drug-eluting stent implantation for long coronary artery stenoses Clinical impact of PCSK9 inhibitor on stabilization and regression of lipid-rich coronary plaques: a near-infrared spectroscopy study Intravascular Ultrasound and Angioscopy Assessment of Coronary Plaque Components in Chronic Totally Occluded Lesions American College of Cardiology Clinical Expert Consensus Document on Standards for Acquisition, Measurement and Reporting of Intravascular Ultrasound Studies (IVUS). A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents Novel predictors of late lumen enlargement in distal reference segments after successful recanalization of coronary chronic total occlusion

Clinical TrialVolume 11, Issue 23, December 2018

JOURNAL:JACC Cardiovasc Interv. Article Link

Sustainable Antirestenosis Effect With a Low-Dose Drug-Coated Balloon: The ILLUMENATE European Randomized Clinical Trial 2-Year Results

M Brodmann, M Werner, the ILLUMENATE EU RCT Investigators. Keywords: claudication; drug-coated balloon; drug-eluting balloon; peripheral artery disease; superficial femoral artery

ABSTRACT


OBJECTIVES - The aim of this study was to assess the safety and effectiveness of a next-generation low-dose drug-coated balloon (DCB) designed to optimize the amount of drug transferred into the vessel wall and to maximize the amount of time the drug resides in the vessel wall.


BACKGROUND - Several randomized controlled studies evaluating various DCBs have demonstrated a significantly higher patency rate compared with noncoated percutaneous transluminal angioplasty balloons at 1 year. However, the data are limited and vary by DCB at longer follow-up time points. An earlier generation low-dose DCB failed to demonstrate significant treatment effect at 2 years, raising questions regarding the durability of low-dose DCBs.


METHODS - In this prospective, multicenter trial, 294 patients were randomized (3:1) to treatment with a DCB or an uncoated percutaneous transluminal angioplasty balloon. Assessments at 2 years included primary patency with duplex ultrasonography, clinically driven target lesion revascularization, and functional outcomes.


RESULTS - Primary patency at 2 years was significantly higher in the DCB cohort (75.9% vs. 61.0%; p = 0.025), and the rate of clinically driven target lesion revascularization was significantly lower (12.1% vs. 30.5%; p < 0.001). There were no major limb amputations in either group. The rates of all-cause (6.5% vs. 5.1%; p = 1.00) and cardiovascular-related (1.6% vs. 1.7%; p = 1.00) mortality were similar between groups. Functional improvements over baseline were sustained in both groups, with 60% fewer reinterventions in the DCB group.


CONCLUSIONS - A sustained treatment effect is achievable with a low-dose DCB with an optimized coating formulation. This trial demonstrated for the first time a statistically significantly higher primary patency rate for a low-dose DCB versus PTA at 2 years. (CVI Drug Coated Balloon European Randomized Clinical Trial; NCT01858363)