CBS 2019
CBSMD教育中心
English

血管内超声指导

科研文章

荐读文献

A Combined Optical Coherence Tomography and Intravascular Ultrasound Study on Plaque Rupture, Plaque Erosion, and Calcified Nodule in Patients With ST-Segment Elevation Myocardial Infarction: Incidence, Morphologic Characteristics, and Outcomes After Percutaneous Coronary Intervention Impact of Positive and Negative Lesion Site Remodeling on Clinical Outcomes : Insights From PROSPECT Intravascular Ultrasound Assessment of In-Stent Restenosis in Saphenous Vein Grafts Usefulness of intravascular ultrasound guidance in percutaneous coronary intervention with second-generation drug-eluting stents for chronic total occlusions (from the Multicenter Korean-Chronic Total Occlusion Registry) Intravascular Ultrasound Guidance Is Associated With Better Outcome in Patients Undergoing Unprotected Left Main Coronary Artery Stenting Compared With Angiography Guidance Alone Intravascular ultrasound-guided drug-eluting stent implantation: An updated meta-analysis of randomized control trials and observational studies Impact of final stent dimensions on long-term results following sirolimus-eluting stent implantation: serial intravascular ultrasound analysis from the sirius trial Is intravascular ultrasound beneficial for percutaneous coronary intervention of bifurcation lesions? Evidence from a 4,314-patient registry Relation between baseline plaque features and subsequent coronary artery remodeling determined by optical coherence tomography and intravascular ultrasound Intravascular ultrasound guidance improves clinical outcomes during implantation of both first- and second-generation drug-eluting stents: a meta-analysis

Clinical TrialVolume 11, Issue 23, December 2018

JOURNAL:JACC Cardiovasc Interv. Article Link

Sustainable Antirestenosis Effect With a Low-Dose Drug-Coated Balloon: The ILLUMENATE European Randomized Clinical Trial 2-Year Results

M Brodmann, M Werner, the ILLUMENATE EU RCT Investigators. Keywords: claudication; drug-coated balloon; drug-eluting balloon; peripheral artery disease; superficial femoral artery

ABSTRACT


OBJECTIVES - The aim of this study was to assess the safety and effectiveness of a next-generation low-dose drug-coated balloon (DCB) designed to optimize the amount of drug transferred into the vessel wall and to maximize the amount of time the drug resides in the vessel wall.


BACKGROUND - Several randomized controlled studies evaluating various DCBs have demonstrated a significantly higher patency rate compared with noncoated percutaneous transluminal angioplasty balloons at 1 year. However, the data are limited and vary by DCB at longer follow-up time points. An earlier generation low-dose DCB failed to demonstrate significant treatment effect at 2 years, raising questions regarding the durability of low-dose DCBs.


METHODS - In this prospective, multicenter trial, 294 patients were randomized (3:1) to treatment with a DCB or an uncoated percutaneous transluminal angioplasty balloon. Assessments at 2 years included primary patency with duplex ultrasonography, clinically driven target lesion revascularization, and functional outcomes.


RESULTS - Primary patency at 2 years was significantly higher in the DCB cohort (75.9% vs. 61.0%; p = 0.025), and the rate of clinically driven target lesion revascularization was significantly lower (12.1% vs. 30.5%; p < 0.001). There were no major limb amputations in either group. The rates of all-cause (6.5% vs. 5.1%; p = 1.00) and cardiovascular-related (1.6% vs. 1.7%; p = 1.00) mortality were similar between groups. Functional improvements over baseline were sustained in both groups, with 60% fewer reinterventions in the DCB group.


CONCLUSIONS - A sustained treatment effect is achievable with a low-dose DCB with an optimized coating formulation. This trial demonstrated for the first time a statistically significantly higher primary patency rate for a low-dose DCB versus PTA at 2 years. (CVI Drug Coated Balloon European Randomized Clinical Trial; NCT01858363)