Role of intravascular ultrasound in patients with acute myocardial infarction undergoing percutaneous coronary intervention Positive remodeling at 3 year follow up is associated with plaque-free coronary wall segment at baseline: a serial IVUS study Defining a new standard for IVUS optimized drug eluting stent implantation: the PRAVIO study Intravascular ultrasound predictors of angiographic restenosis after sirolimus-eluting stent implantation Impact of Intravascular Ultrasound on Long-Term Clinical Outcomes in Patients With Acute Myocardial Infarction Mechanisms of in-stent restenosis after drug-eluting stent implantation: intravascular ultrasound analysis Impact of post-intervention minimal stent area on 9-month follow-up patency of paclitaxel-eluting stents: an integrated intravascular ultrasound analysis from the TAXUS IV, V, and VI and TAXUS ATLAS Workhorse, Long Lesion, and Direct Stent Trials The role of integrated backscatter intravascular ultrasound in characterizing bare metal and drug-eluting stent restenotic neointima as compared to optical coherence tomography Intravascular Ultrasound Guidance vs. Angiographic Guidance in Primary Percutaneous Coronary Intervention for ST-Segment Elevation Myocardial Infarction - Long-Term Clinical Outcomes From the CREDO-Kyoto AMI Registry Correlations between fractional flow reserve and intravascular ultrasound in patients with an ambiguous left main coronary artery stenosis

Clinical TrialVolume 11, Issue 23, December 2018

JOURNAL:JACC Cardiovasc Interv. Article Link

Sustainable Antirestenosis Effect With a Low-Dose Drug-Coated Balloon: The ILLUMENATE European Randomized Clinical Trial 2-Year Results

M Brodmann, M Werner, the ILLUMENATE EU RCT Investigators. Keywords: claudication; drug-coated balloon; drug-eluting balloon; peripheral artery disease; superficial femoral artery

ABSTRACT


OBJECTIVES - The aim of this study was to assess the safety and effectiveness of a next-generation low-dose drug-coated balloon (DCB) designed to optimize the amount of drug transferred into the vessel wall and to maximize the amount of time the drug resides in the vessel wall.


BACKGROUND - Several randomized controlled studies evaluating various DCBs have demonstrated a significantly higher patency rate compared with noncoated percutaneous transluminal angioplasty balloons at 1 year. However, the data are limited and vary by DCB at longer follow-up time points. An earlier generation low-dose DCB failed to demonstrate significant treatment effect at 2 years, raising questions regarding the durability of low-dose DCBs.


METHODS - In this prospective, multicenter trial, 294 patients were randomized (3:1) to treatment with a DCB or an uncoated percutaneous transluminal angioplasty balloon. Assessments at 2 years included primary patency with duplex ultrasonography, clinically driven target lesion revascularization, and functional outcomes.


RESULTS - Primary patency at 2 years was significantly higher in the DCB cohort (75.9% vs. 61.0%; p = 0.025), and the rate of clinically driven target lesion revascularization was significantly lower (12.1% vs. 30.5%; p < 0.001). There were no major limb amputations in either group. The rates of all-cause (6.5% vs. 5.1%; p = 1.00) and cardiovascular-related (1.6% vs. 1.7%; p = 1.00) mortality were similar between groups. Functional improvements over baseline were sustained in both groups, with 60% fewer reinterventions in the DCB group.


CONCLUSIONS - A sustained treatment effect is achievable with a low-dose DCB with an optimized coating formulation. This trial demonstrated for the first time a statistically significantly higher primary patency rate for a low-dose DCB versus PTA at 2 years. (CVI Drug Coated Balloon European Randomized Clinical Trial; NCT01858363)