Effects of Intravascular Ultrasound-Guided Versus Angiography-Guided New-Generation Drug-Eluting Stent Implantation: Meta-Analysis With Individual Patient-Level Data From 2,345 Randomized Patients Consensus from the 5th European Bifurcation Club meeting Impact of Intravascular Ultrasound-Guided Percutaneous Coronary Intervention on Long-Term Clinical Outcomes in Patients Undergoing Complex Procedures Comparison of paclitaxel-eluting stents (Taxus) and everolimus-eluting stents (Xience) in left main coronary artery disease with 3 years follow-up (from the ESTROFA-LM registry) Intravascular ultrasound-derived minimal lumen area criteria for functionally significant left main coronary artery stenosis Intravascular Ultrasound Parameters Associated With Stent Thrombosis After Drug-Eluting Stent Deployment Defining a new standard for IVUS optimized drug eluting stent implantation: the PRAVIO study Contribution of stent underexpansion to recurrence after sirolimus-eluting stent implantation for in-stent restenosis

Expert Opinion2019 Feb 16. [Epub ahead of print]

JOURNAL:J Am Coll Cardiol. Article Link

Recommendations for Institutions Transitioning to High-Sensitivity Troponin Testing JACC Scientific Expert Panel

Januzzi JL Jr, Mahler SA, Christenson RH et al. Keywords: laboratory testing; myocardial infarction; troponin

ABSTRACT


High-sensitivity cardiac troponin (hs-cTn) I or T methods have been in use in certain regions for years but are now increasingly globally adopted, including in the United States. Accordingly, inevitable challenges are created for institutions transitioning from conventional cardiac troponin (cTn) assays. hs-cTn assays have higher analytic precision at lower concentrations, yielding greater clinical sensitivity for myocardial injury and allowing accurate recognition of small changes in troponin concentration (rise or fall) within a short time frame. Although much of the knowledge regarding troponin biology that was applicable with older troponin assays still holds true, considerable education regarding the differences between conventional cTn and hs-cTn is needed before medical systems convert to the newer methods. This includes a basic understanding of how hs-cTn testing differs from conventional cTn testing and how it is best deployed in different settings, such as the emergency department and inpatient services. This Expert Panel will review important concepts for institutional transition to hs-cTn methodology, providing recommendations useful for education before implementation.


Copyright ? 2019 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.