CBS 2019
CBSMD教育中心
中 文

DAPT Duration

Abstract

Recommended Article

A randomized comparison of Coronary Stents according to Short or Prolonged durations of Dual Antiplatelet Therapy in patients with Acute Coronary Syndromes: a pre-specified analysis of the SMART-DATE trial Antiplatelet therapy in patients with myocardial infarction without obstructive coronary artery disease The optimal duration of dual antiplatelet therapy after coronary stent implantation: to go too far is as bad as to fall short Ticagrelor with or without Aspirin in High-Risk Patients after PCI A risk score to predict postdischarge bleeding among acute coronary syndrome patients undergoing percutaneous coronary intervention: BRIC-ACS study Efficacy and Safety of Ticagrelor Monotherapy in Patients Undergoing Multivessel PCI Primary Results of the EVOLVE Short DAPT Study: Evaluation of 3-Month Dual Antiplatelet Therapy in High Bleeding Risk Patients Treated With a Bioabsorbable Polymer-Coated Everolimus-Eluting Stent Optimal duration of dual antiplatelet therapy after drug-eluting stent implantation: a randomized, controlled trial.

Original Research2013 May 15;111(10):1408-14.

JOURNAL:Am J Cardiol. Article Link

Intravascular ultrasound predictors for edge restenosis after newer generation drug-eluting stent implantation

Kang SJ, Cho YR, Park GM et al. Keywords: IVUS; edge stenosis; DES

ABSTRACT


The aim of the present study was to assess the intravascular ultrasound predictors for angiographic edge restenosis after newer generation drug-eluting stent implantation. A total of 820 patients (987 lesions) who underwent newer generation drug-eluting stent placement (236 Endeavor zotarolimus-eluting stents, 246 Resolute zotarolimus-eluting stents, and 505 everolimus-eluting stents) with 9 months of angiographic surveillance were enrolled. The post-stenting angiographic and intravascular ultrasound images of 1,668 reference segments (681 proximal and 987 distal) were analyzed. Overall, 37% of angiographically normal proximal reference segments and 21% of angiographically normal distal reference segments had plaque burden >50%. In the overall cohort of 1,668 reference segments, 47 (2.8%) had 9-month angiographic edge restenosis (diameter stenosis >50%). Edge restenosis was predicted by a post-stenting reference segment plaque burden >54.5% (sensitivity 81%, specificity 80%) and a reference segment minimum lumen area of 5.7 mm(2) (sensitivity 72%, specificity 59%). The edge restenosis rate was 2.1% in the Endeavor zotarolimus-eluting stents, 2.4% in the Resolute zotarolimus-eluting stents, and 3.4% in the everolimus-eluting stents lesions (p = 0.311). The predictive cutoff of the reference plaque burden was 56.3% for Endeavor zotarolimus-eluting stents, 57.3% for Resolute zotarolimus-eluting stents, and 54.2% for everolimus-eluting stents. The criteria for residual plaque burden were similar between proximal and distal reference segments (56.4% vs 51.9%, respectively), but the minimum lumen area criteria were quite different (<7.1 mm(2) for proximal vs <4.8 mm(2) for distal reference segments). In conclusion, after newer drug-eluting stent implantation, edge restenosis was predicted by post-stenting reference segment plaque burden >55%.