CBS 2019
CBSMD教育中心
中 文

DAPT Duration

Abstract

Recommended Article

Individualized antiplatelet therapy after drug-eluting stent deployment: Implication of clinical trials of different durations of dual antiplatelet therapy Management of Antithrombotic Therapy in Atrial Fibrillation Patients Undergoing PCI: JACC State-of-the-Art Review Dual Antiplatelet Therapy after PCI in Patients at High Bleeding Risk Prasugrel versus clopidogrel in patients with acute coronary syndromes Polymer-based or Polymer-free Stents in Patients at High Bleeding Risk P2Y12 Inhibitor Monotherapy with Clopidogrel Versus Ticagrelor in Patients with Acute Coronary Syndrome Undergoing Percutaneous Coronary Intervention Dual antiplatelet therapy: how, how long, and in which patients? A new strategy for discontinuation of dual antiplatelet therapy: the RESET Trial (REal Safety and Efficacy of 3-month dual antiplatelet Therapy following Endeavor zotarolimus-eluting stent implantation)

Original Research2013 May 15;111(10):1408-14.

JOURNAL:Am J Cardiol. Article Link

Intravascular ultrasound predictors for edge restenosis after newer generation drug-eluting stent implantation

Kang SJ, Cho YR, Park GM et al. Keywords: IVUS; edge stenosis; DES

ABSTRACT


The aim of the present study was to assess the intravascular ultrasound predictors for angiographic edge restenosis after newer generation drug-eluting stent implantation. A total of 820 patients (987 lesions) who underwent newer generation drug-eluting stent placement (236 Endeavor zotarolimus-eluting stents, 246 Resolute zotarolimus-eluting stents, and 505 everolimus-eluting stents) with 9 months of angiographic surveillance were enrolled. The post-stenting angiographic and intravascular ultrasound images of 1,668 reference segments (681 proximal and 987 distal) were analyzed. Overall, 37% of angiographically normal proximal reference segments and 21% of angiographically normal distal reference segments had plaque burden >50%. In the overall cohort of 1,668 reference segments, 47 (2.8%) had 9-month angiographic edge restenosis (diameter stenosis >50%). Edge restenosis was predicted by a post-stenting reference segment plaque burden >54.5% (sensitivity 81%, specificity 80%) and a reference segment minimum lumen area of 5.7 mm(2) (sensitivity 72%, specificity 59%). The edge restenosis rate was 2.1% in the Endeavor zotarolimus-eluting stents, 2.4% in the Resolute zotarolimus-eluting stents, and 3.4% in the everolimus-eluting stents lesions (p = 0.311). The predictive cutoff of the reference plaque burden was 56.3% for Endeavor zotarolimus-eluting stents, 57.3% for Resolute zotarolimus-eluting stents, and 54.2% for everolimus-eluting stents. The criteria for residual plaque burden were similar between proximal and distal reference segments (56.4% vs 51.9%, respectively), but the minimum lumen area criteria were quite different (<7.1 mm(2) for proximal vs <4.8 mm(2) for distal reference segments). In conclusion, after newer drug-eluting stent implantation, edge restenosis was predicted by post-stenting reference segment plaque burden >55%.