CBS 2019
CBSMD教育中心
中 文

DAPT Duration

Abstract

Recommended Article

Six Versus 12 Months of Dual Antiplatelet Therapy After Implantation of Biodegradable Polymer Sirolimus-Eluting Stent: Randomized Substudy of the I-LOVE-IT 2 Trial Comparison of 1-month Versus 12-month Dual Antiplatelet Therapy after Implantation of Drug-eluting Stents Guided by either Intravascular Ultrasound or Angiography in Patients with Acute Coronary Syndrome: Rationale and Design of Prospective, Multicenter, Randomized, Controlled IVUS-ACS & ULTIMATE-DAPT trial Inhibition of Platelet Aggregation After Coronary Stenting in Patients Receiving Oral Anticoagulation Mortality Following Cardiovascular and Bleeding Events Occurring Beyond 1 Year After Coronary Stenting - A Secondary Analysis of the Dual Antiplatelet Therapy (DAPT) Study Elaborately Engineering a Self-Indicating Dual-Drug Nanoassembly for Site-Specific Photothermal-Potentiated Thrombus Penetration and Thrombolysis Dual Antiplatelet Therapy Duration in Medically Managed Acute Coronary Syndrome Patients: Sub-Analysis of the OPT-CAD Study 6-month versus 12-month or longer dual antiplatelet therapy after percutaneous coronary intervention in patients with acute coronary syndrome (SMART-DATE): a randomised, open-label, non-inferiority trial 2016 ACC/AHA guideline focused update on duration of dual antiplatelet therapy in patients with coronary artery disease: A report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines

Original Research2007 May;71(5):648-53.

JOURNAL:Circ J. Article Link

Atherosclerotic plaque with ultrasonic attenuation affects coronary reflow and infarct size in patients with acute coronary syndrome: an intravascular ultrasound study

Okura H, Taguchi H, Kubo T et al. Keywords: Arrhythmia; Coronary circulation; Stent

ABSTRACT


BACKGROUNDNo reflow following percutaneous coronary intervention (PCI) is a major concern in patients with acute coronary syndrome (ACS) and it may be influenced by the preexisting plaque type.


METHODS AND RESULTSTo evaluate the impact of plaque characteristics on coronary reflow following PCI in patients with ACS, a total of 110 patients (89 acute myocardial infarction, 21 unstable angina) were assessed by intravascular ultrasound. Plaque type was categorized as either atherosclerotic plaque without ultrasonic attenuation (group 1) or atherosclerotic plaque with attenuation (group 2). External elastic membrane, plaque plus media, and lumen area were measured. Coronary flow was assessed by Thrombolysis in Myocardial Infarction (TIMI) grade and TIMI frame count. Although the final TIMI frame count was similar between the 2 groups, TIMI frame count immediately after the first balloon inflation was significantly higher in group 2 (p=0.03). Despite the similar final TIMI grade and TIMI frame count, peak creatine kinase level was significantly higher (3,035+/-2,553 vs 1,950+/-1,958 IU/L, p=0.04) and fatal arrhythmia more frequently observed (16.4% vs 2.7%, p=0.04) in group 2 than in group 1.

CONCLUSIONSAtherosclerotic plaque with ultrasonic attenuation may be related to a transient deterioration in coronary flow and as a result larger infarct size and higher incidence of fatal arrhythmia following PCI in patients with ACS. These results may help in selecting lesions suitable for distal protection devices.