CBS 2019
CBSMD教育中心
中 文

DAPT Duration

Abstract

Recommended Article

Patient-oriented composite endpoints and net adverse clinical events with ticagrelor monotherapy following percutaneous coronary intervention: Insights from the randomized GLOBAL LEADERS trial Antibody-Based Ticagrelor Reversal Agent in Healthy Volunteers Dual Antiplatelet Therapy Duration: Reconciling the Inconsistencies Dual Antithrombotic Therapy with Dabigatran after PCI in Atrial Fibrillation Dual Antiplatelet TherapyIs It Time to Cut the Cord With Aspirin? Prevention of Bleeding in Patients with Atrial Fibrillation Undergoing PCI ACC/AHA Versus ESC Guidelines on Dual Antiplatelet Therapy JACC Guideline Comparison: JACC State-of-the-Art Review Ticagrelor plus aspirin for 1 month, followed by ticagrelor monotherapy for 23 months versus aspirin plus clopidogrel or ticagrelor for 12 months, followed by aspirin monotherapy for 12 months after implantation of a drug-eluting stent: a multicenter, open-label, randomized superiority trial

Original Research2007 May;71(5):648-53.

JOURNAL:Circ J. Article Link

Atherosclerotic plaque with ultrasonic attenuation affects coronary reflow and infarct size in patients with acute coronary syndrome: an intravascular ultrasound study

Okura H, Taguchi H, Kubo T et al. Keywords: Arrhythmia; Coronary circulation; Stent

ABSTRACT


BACKGROUNDNo reflow following percutaneous coronary intervention (PCI) is a major concern in patients with acute coronary syndrome (ACS) and it may be influenced by the preexisting plaque type.


METHODS AND RESULTSTo evaluate the impact of plaque characteristics on coronary reflow following PCI in patients with ACS, a total of 110 patients (89 acute myocardial infarction, 21 unstable angina) were assessed by intravascular ultrasound. Plaque type was categorized as either atherosclerotic plaque without ultrasonic attenuation (group 1) or atherosclerotic plaque with attenuation (group 2). External elastic membrane, plaque plus media, and lumen area were measured. Coronary flow was assessed by Thrombolysis in Myocardial Infarction (TIMI) grade and TIMI frame count. Although the final TIMI frame count was similar between the 2 groups, TIMI frame count immediately after the first balloon inflation was significantly higher in group 2 (p=0.03). Despite the similar final TIMI grade and TIMI frame count, peak creatine kinase level was significantly higher (3,035+/-2,553 vs 1,950+/-1,958 IU/L, p=0.04) and fatal arrhythmia more frequently observed (16.4% vs 2.7%, p=0.04) in group 2 than in group 1.

CONCLUSIONSAtherosclerotic plaque with ultrasonic attenuation may be related to a transient deterioration in coronary flow and as a result larger infarct size and higher incidence of fatal arrhythmia following PCI in patients with ACS. These results may help in selecting lesions suitable for distal protection devices.