双重抗血小板治疗持续时间

Abstract

Recommended Article

Bleeding-Related Deaths in Relation to the Duration of Dual-Antiplatelet Therapy After Coronary Stenting Mortality Following Cardiovascular and Bleeding Events Occurring Beyond 1 Year After Coronary Stenting - A Secondary Analysis of the Dual Antiplatelet Therapy (DAPT) Study Benefit of switching dual antiplatelet therapy after acute coronary syndrome: the TOPIC (timing of platelet inhibition after acute coronary syndrome) randomized study Dual Antithrombotic Therapy with Dabigatran after PCI in Atrial Fibrillation Risk of Early Adverse Events After Clopidogrel Discontinuation in Patients Undergoing Short-Term Dual Antiplatelet Therapy: An Individual Participant Data Analysis Low-Dose Aspirin Discontinuation and Risk of Cardiovascular Events: A Swedish Nationwide, Population-Based Cohort Study Characterization of the Average Daily Ischemic and Bleeding Risk After Primary PCI for STEMI Patterns and associations between DAPT cessation and 2-year clinical outcomes in left main/proximal LAD versus other PCI: Results from the Patterns of Non-Adherence to Dual Antiplatelet Therapy in Stented Patients (PARIS) registry

Clinical Trial2018 Jan 1;19(1):59-66.

JOURNAL:Eur Heart J Cardiovasc Imaging. Article Link

Fate of post-procedural malapposition of everolimus-eluting polymeric bioresorbable scaffold and everolimus-eluting cobalt chromium metallic stent in human coronary arteries: sequential assessment with optical coherence tomography in ABSORB Japan trial

Sotomi Y, Onuma Y, Dijkstra J et al. Keywords: bioresorbable scaffold ; metallic stent ; optical coherence tomography ; randomized controlled trial; strut malapposition

ABSTRACT


AIMS - The natural course of post-procedural incomplete strut apposition (ISA) after the implantation of bioresorbable scaffolds (BVS) remains unknown. The purpose of the present study was to evaluate the fate of post-procedural ISA after everolimus-eluting Absorb BVS in comparison with the second-generation everolimus-eluting cobalt chromium stent (CoCr-EES).


METHODS AND RESULTS - Fate of post-procedural ISA was evaluated by serial optical coherence tomography(OCT) in the ABSORB Japan randomized trial [OCT-1 subgroup: 110 paired lesions of post-procedure and 2-year follow-up (BVS 73 lesions vs. CoCr-EES 37 lesions)] with respect to ISA distance. Post-procedure ISA struts were categorized into either 'resolved' or 'persistent' by matched OCT imaging at 2-year follow-up. Post-procedure %malapposed strut and ISA area were smaller in BVS than in CoCr-EES (%malapposed strut: 4.8 ± 6.9% vs. 9.9 ± 9.8%, P = 0.002; ISA area 0.10 ± 0.18 mm2 vs. 0.23 ± 0.26 mm2, P = 0.003). At 2-year follow-up, the difference diminished, and majority of the ISA struts spontaneously resolved in both arms (%malapposed strut: 0.10 ± 0.46% vs. 0.24 ± 0.65%, P = 0.183). Receiver operating characteristic curve analysis (BVS 661 struts vs. CoCr-EES 807 struts) demonstrated that the best cut-off value of endoluminal ISA distance post-procedure for predicting persistent-ISA at 2-year follow-up was 396 µm for BVS (sensitivity 0.875; specificity 0.851) and 359 µm for CoCr-EES (sensitivity 0.778; specificity 0.881).


CONCLUSION - BVS as compared with CoCr-EES allows larger ISA distance at post-procedure, although we should make every effort to minimize post-procedure ISA. The reported cut-off value of OCT-estimated ISA distance at post-stenting for predicting persistent-ISA would be helpful to optimize PCI with BVS and CoCr-EES.