Aspirin-Free Prasugrel Monotherapy Following Coronary Artery Stenting in Patients With Stable CAD: The ASET Pilot Study State of the art: duration of dual antiplatelet therapy after percutaneous coronary intervention and coronary stent implantation - past, present and future perspectives. Ticagrelor plus aspirin for 1 month, followed by ticagrelor monotherapy for 23 months versus aspirin plus clopidogrel or ticagrelor for 12 months, followed by aspirin monotherapy for 12 months after implantation of a drug-eluting stent: a multicenter, open-label, randomized superiority trial Causes, Timing, and Impact of Dual Antiplatelet Therapy Interruption for Surgery (from the Patterns of Non-adherence to Anti-platelet Regimens In Stented Patients Registry) Ticagrelor with or without Aspirin in High-Risk Patients after PCI The optimal duration of dual antiplatelet therapy after coronary stent implantation: to go too far is as bad as to fall short Prevention of Bleeding in Patients with Atrial Fibrillation Undergoing PCI 2016 ACC/AHA guideline focused update on duration of dual antiplatelet therapy in patients with coronary artery disease: A report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines

Clinical Trial2018 Jan 1;19(1):59-66.

JOURNAL:Eur Heart J Cardiovasc Imaging. Article Link

Fate of post-procedural malapposition of everolimus-eluting polymeric bioresorbable scaffold and everolimus-eluting cobalt chromium metallic stent in human coronary arteries: sequential assessment with optical coherence tomography in ABSORB Japan trial

Sotomi Y, Onuma Y, Dijkstra J et al. Keywords: bioresorbable scaffold ; metallic stent ; optical coherence tomography ; randomized controlled trial; strut malapposition

ABSTRACT


AIMS - The natural course of post-procedural incomplete strut apposition (ISA) after the implantation of bioresorbable scaffolds (BVS) remains unknown. The purpose of the present study was to evaluate the fate of post-procedural ISA after everolimus-eluting Absorb BVS in comparison with the second-generation everolimus-eluting cobalt chromium stent (CoCr-EES).


METHODS AND RESULTS - Fate of post-procedural ISA was evaluated by serial optical coherence tomography(OCT) in the ABSORB Japan randomized trial [OCT-1 subgroup: 110 paired lesions of post-procedure and 2-year follow-up (BVS 73 lesions vs. CoCr-EES 37 lesions)] with respect to ISA distance. Post-procedure ISA struts were categorized into either 'resolved' or 'persistent' by matched OCT imaging at 2-year follow-up. Post-procedure %malapposed strut and ISA area were smaller in BVS than in CoCr-EES (%malapposed strut: 4.8 ± 6.9% vs. 9.9 ± 9.8%, P = 0.002; ISA area 0.10 ± 0.18 mm2 vs. 0.23 ± 0.26 mm2, P = 0.003). At 2-year follow-up, the difference diminished, and majority of the ISA struts spontaneously resolved in both arms (%malapposed strut: 0.10 ± 0.46% vs. 0.24 ± 0.65%, P = 0.183). Receiver operating characteristic curve analysis (BVS 661 struts vs. CoCr-EES 807 struts) demonstrated that the best cut-off value of endoluminal ISA distance post-procedure for predicting persistent-ISA at 2-year follow-up was 396 µm for BVS (sensitivity 0.875; specificity 0.851) and 359 µm for CoCr-EES (sensitivity 0.778; specificity 0.881).


CONCLUSION - BVS as compared with CoCr-EES allows larger ISA distance at post-procedure, although we should make every effort to minimize post-procedure ISA. The reported cut-off value of OCT-estimated ISA distance at post-stenting for predicting persistent-ISA would be helpful to optimize PCI with BVS and CoCr-EES.