CBS 2019
CBSMD教育中心
中 文

Rotational Atherectomy

Abstract

Recommended Article

Effect of orbital atherectomy in calcified coronary artery lesions as assessed by optical coherence tomography In vivo comparison of lipid-rich plaque on near-infrared spectroscopy with histopathological analysis of coronary atherectomy specimens Incremental Prognostic Value of Guideline-Directed Medical Therapy, Transradial Access, and Door-to-Balloon Time on Outcomes in ST-Segment-Elevation Myocardial Infarction State of the art: evolving concepts in the treatment of heavily calcified and undilatable coronary stenoses - from debulking to plaque modification, a 40-year-long journey Rotational atherectomy and new-generation drug-eluting stent implantation Optical frequency-domain imaging findings to predict good stent expansion after rotational atherectomy for severely calcified coronary lesions Short-term and long-term clinical outcomes of rotational atherectomy in resistant chronic total occlusion Radial Versus Femoral Access for Rotational Atherectomy: A UK Observational Study of 8622 Patients

Clinical Case Study2018 Feb 2;13(15):e1812-e1813.

JOURNAL:EuroIntervention. Article Link

Influence of the sequence of proximal optimisation technique and side branch dilation for the opening of jailed struts after coronary bifurcation stenting

Murasato Y, Mori T, Okamura T et al. Keywords: proximal optimisation technique; side branch dilation; jailed struts; coronary bifurcation stenting

ABSTRACT


A 67-year-old man with a 1,1,0 lesion in the left circumflex artery obtuse marginal branch bifurcation (Panel Aa), in which vessel references in the proximal, distal MV and SB were 3.2, 2.6, and 2.8 mm, respectively, underwent zotarolimus-eluting 2.75×12 mm stent (Medtronic, Minneapolis, MN, USA) implantation at 8 atm (Panel Ab). POT was performed with the stent delivery balloon at 12 atm with its distal marker located in the carina to ensure that the stent was well apposed (Panel Ac). A 2.5×4 mm Glider PTCA balloon (TriReme, Pleasanton, CA, USA) was subsequently dilated in the SB ostium (Panel Ad). The procedure was guided with two-dimensional (2D) OCT (St. Jude Medical, St. Paul, MN, USA) and the data were sent to another hospital for 3D reconstruction using dedicated software (INTAGE Realia; CYBERNET, Tokyo, Japan). The 3D image demonstrated GWR into the proximal cell (Panel Ba); however, the protruded struts were folded towards the distal SB after SB dilation (Panel Bb-Bd, Moving image 1, Moving image 2).