CBS 2019
CBSMD教育中心
中 文

Rotational Atherectomy

Abstract

Recommended Article

Transverse partial stent ablation with rotational atherectomy for suboptimal culotte technique in left main stem bifurcation A Meta-Analysis of Contemporary Lesion Modification Strategies During Percutaneous Coronary Intervention in 244,795 Patients From 22 Studies Healed coronary plaque rupture as a cause of rapid lesion progression: a case demonstrated with in vivo histopathology by directional coronary atherectomy Five-Year Clinical Outcomes After Drug-Eluting Stent Implantation Following Rotational Atherectomy for Heavily Calcified Lesions Two-year outcomes after treatment of severely calcified coronary lesions with the orbital atherectomy system and the impact of stent types: Insight from the ORBIT II trial Multicenter Registry of Real-World Patients With Severely Calcified Coronary Lesions Undergoing Orbital Atherectomy: 1-Year Outcomes Trends in Utilization of, and Comparative Safety and Effectiveness of Orbital and Rotational Atherectomy Long-term clinical outcomes of permanent polymer everolimus-eluting stent implantation following rotational atherectomy for severely calcified de novo coronary lesions: Results of a 22-center study (Tokyo-MD PCI Study)

Clinical Case Study2018 Feb 2;13(15):e1812-e1813.

JOURNAL:EuroIntervention. Article Link

Influence of the sequence of proximal optimisation technique and side branch dilation for the opening of jailed struts after coronary bifurcation stenting

Murasato Y, Mori T, Okamura T et al. Keywords: proximal optimisation technique; side branch dilation; jailed struts; coronary bifurcation stenting

ABSTRACT


A 67-year-old man with a 1,1,0 lesion in the left circumflex artery obtuse marginal branch bifurcation (Panel Aa), in which vessel references in the proximal, distal MV and SB were 3.2, 2.6, and 2.8 mm, respectively, underwent zotarolimus-eluting 2.75×12 mm stent (Medtronic, Minneapolis, MN, USA) implantation at 8 atm (Panel Ab). POT was performed with the stent delivery balloon at 12 atm with its distal marker located in the carina to ensure that the stent was well apposed (Panel Ac). A 2.5×4 mm Glider PTCA balloon (TriReme, Pleasanton, CA, USA) was subsequently dilated in the SB ostium (Panel Ad). The procedure was guided with two-dimensional (2D) OCT (St. Jude Medical, St. Paul, MN, USA) and the data were sent to another hospital for 3D reconstruction using dedicated software (INTAGE Realia; CYBERNET, Tokyo, Japan). The 3D image demonstrated GWR into the proximal cell (Panel Ba); however, the protruded struts were folded towards the distal SB after SB dilation (Panel Bb-Bd, Moving image 1, Moving image 2).