CBS 2019
CBSMD教育中心
中 文

Rotational Atherectomy

Abstract

Recommended Article

One-Year Outcomes of Orbital Atherectomy of Long, Diffusely Calcified Coronary Artery Lesions Orbital atherectomy for the treatment of small (2.5mm) severely calcified coronary lesions: ORBIT II sub-analysis Outcomes After Orbital Atherectomy of Severely Calcified Left Main Lesions: Analysis of the ORBIT II Study Long-term outcomes of rotational atherectomy of underexpanded stents. A single center experience Temporal changes in radial access use, associates and outcomes in patients undergoing PCI using rotational atherectomy between 2007 and 2014: results from the British Cardiovascular Intervention Society national database Clinical Characteristics and Long-Term Outcomes of Rotational Atherectomy-J2T Multicenter Registry Pivotal trial to evaluate the safety and efficacy of the orbital atherectomy system in treating de novo, severely calcified coronary lesions (ORBIT II) Orbital atherectomy for treating de novo, severely calcified coronary lesions: 3-year results of the pivotal ORBIT II trial

Clinical Case Study2018 Feb 2;13(15):e1812-e1813.

JOURNAL:EuroIntervention. Article Link

Influence of the sequence of proximal optimisation technique and side branch dilation for the opening of jailed struts after coronary bifurcation stenting

Murasato Y, Mori T, Okamura T et al. Keywords: proximal optimisation technique; side branch dilation; jailed struts; coronary bifurcation stenting

ABSTRACT


A 67-year-old man with a 1,1,0 lesion in the left circumflex artery obtuse marginal branch bifurcation (Panel Aa), in which vessel references in the proximal, distal MV and SB were 3.2, 2.6, and 2.8 mm, respectively, underwent zotarolimus-eluting 2.75×12 mm stent (Medtronic, Minneapolis, MN, USA) implantation at 8 atm (Panel Ab). POT was performed with the stent delivery balloon at 12 atm with its distal marker located in the carina to ensure that the stent was well apposed (Panel Ac). A 2.5×4 mm Glider PTCA balloon (TriReme, Pleasanton, CA, USA) was subsequently dilated in the SB ostium (Panel Ad). The procedure was guided with two-dimensional (2D) OCT (St. Jude Medical, St. Paul, MN, USA) and the data were sent to another hospital for 3D reconstruction using dedicated software (INTAGE Realia; CYBERNET, Tokyo, Japan). The 3D image demonstrated GWR into the proximal cell (Panel Ba); however, the protruded struts were folded towards the distal SB after SB dilation (Panel Bb-Bd, Moving image 1, Moving image 2).