Abstract

Recommended Article

Use of Mechanical Circulatory Support Devices Among Patients With Acute Myocardial Infarction Complicated by Cardiogenic Shock Association Between Collateral Circulation and Myocardial Viability Evaluated by Cardiac Magnetic Resonance Imaging in Patients With Coronary Artery Chronic Total Occlusion Evaluation and Management of Nonculprit Lesions in STEMI Prognostic Value of the Residual SYNTAX Score After Functionally Complete Revascularization in ACS Prognostic value of fibrinogen in patients with coronary artery disease and prediabetes or diabetes following percutaneous coronary intervention: 5-year findings from a large cohort study Heart Regeneration by Endogenous Stem Cells and Cardiomyocyte Proliferation: Controversy, Fallacy, and Progress A randomised trial comparing two stent sizing strategies in coronary bifurcation treatment with bioresorbable vascular scaffolds - The Absorb Bifurcation Coronary (ABC) trial Prognostic and Practical Validation of Current Definitions of Myocardial Infarction Associated With Percutaneous Coronary Intervention

Review Article2018 Nov 29.

JOURNAL:Catheter Cardiovasc Interv. Article Link

Outcomes with drug-coated balloons in small-vessel coronary artery disease

Megaly M, Rofael M, Saad M et al. Keywords: drug-coated balloons; drug-eluting balloons; small-vessel disease coronary disease

ABSTRACT


BACKGROUND - Percutaneous coronary intervention (PCI) of small-vessel coronary artery disease (SVD) is associated with increased risk of restenosis. The use of drug-coated balloons (DCBs) in SVD has received limited study.


OBJECTIVES - To assess the outcomes of DCB in the treatment of SVD compared with the standard of care.


METHODS - We performed a meta-analysis of all studies published between January 2000 and September 2018 reporting the outcomes of DCB versus other modalities in the treatment of de novo SVD.


RESULTS - Seven studies with 1,824 patients (1,938 lesions) were included (four randomized controlled trials and three observational studies). During a mean follow-up of 14.5 ± 10 months, DCBs were associated with a similar risk of target lesion revascularization (TLR) (OR: 0.99, 95% CI: 0.54, 1.84, P = 0.97) and major adverse cardiovascular events (MACE) (OR: 0.86, 95% CI: 0.51, 1.45, P = 0.57) compared with drug-eluting stents (DES). During a mean follow-up of 7 ± 1.5 months, DCBs were associated with a significantly lower risk of TLR (OR: 0.19, 95% CI 0.04-0.88, P = 0.03) and binary restenosis (OR: 0.17, 95% CI 0.08-0.37, P = <0.00001) compared with noncoated balloon angioplasty.


CONCLUSION - The use of DCBs in SVD is associated with comparable outcomes when compared with DES and favorable outcomes when compared with balloon angioplasty.