CBS 2019
CBSMD教育中心
中 文

急性冠脉综合征

Abstract

Recommended Article

Long-Term Outcomes of Patients With Late Presentation of ST-Segment Elevation Myocardial Infarction Triage Considerations for Patients Referred for Structural Heart Disease Intervention During the Coronavirus Disease 2019 (COVID-19) Pandemic: An ACC /SCAI Consensus Statement Galectin-3 Levels and Outcomes After Myocardial Infarction: A Population-Based Study Early Natural History of Spontaneous Coronary Artery Dissection Prevalence of Coronary Vasospasm Using Coronary Reactivity Testing in Patients With Spontaneous Coronary Artery Dissection Radial versus femoral access and bivalirudin versus unfractionated heparin in invasively managed patients with acute coronary syndrome (MATRIX): final 1-year results of a multicentre, randomised controlled trial Effect of Pre-Hospital Crushed Prasugrel Tablets in Patients with STEMI Planned for Primary Percutaneous Coronary Intervention: The Randomized COMPARE CRUSH Trial Effect of Medication Co-payment Vouchers on P2Y12 Inhibitor Use and Major Adverse Cardiovascular Events Among Patients With Myocardial Infarction: The ARTEMIS Randomized Clinical Trial

Review Article2018 Nov 29.

JOURNAL:Catheter Cardiovasc Interv. Article Link

Outcomes with drug-coated balloons in small-vessel coronary artery disease

Megaly M, Rofael M, Saad M et al. Keywords: drug-coated balloons; drug-eluting balloons; small-vessel disease coronary disease

ABSTRACT


BACKGROUND - Percutaneous coronary intervention (PCI) of small-vessel coronary artery disease (SVD) is associated with increased risk of restenosis. The use of drug-coated balloons (DCBs) in SVD has received limited study.


OBJECTIVES - To assess the outcomes of DCB in the treatment of SVD compared with the standard of care.


METHODS - We performed a meta-analysis of all studies published between January 2000 and September 2018 reporting the outcomes of DCB versus other modalities in the treatment of de novo SVD.


RESULTS - Seven studies with 1,824 patients (1,938 lesions) were included (four randomized controlled trials and three observational studies). During a mean follow-up of 14.5 ± 10 months, DCBs were associated with a similar risk of target lesion revascularization (TLR) (OR: 0.99, 95% CI: 0.54, 1.84, P = 0.97) and major adverse cardiovascular events (MACE) (OR: 0.86, 95% CI: 0.51, 1.45, P = 0.57) compared with drug-eluting stents (DES). During a mean follow-up of 7 ± 1.5 months, DCBs were associated with a significantly lower risk of TLR (OR: 0.19, 95% CI 0.04-0.88, P = 0.03) and binary restenosis (OR: 0.17, 95% CI 0.08-0.37, P = <0.00001) compared with noncoated balloon angioplasty.


CONCLUSION - The use of DCBs in SVD is associated with comparable outcomes when compared with DES and favorable outcomes when compared with balloon angioplasty.

© 2018 Wiley Periodicals, Inc.