Dabigatran dual therapy with ticagrelor or clopidogrel after percutaneous coronary intervention in atrial fibrillation patients with or without acute coronary syndrome: a subgroup analysis from the RE-DUAL PCI trial Anticoagulation in Concomitant Chronic Kidney Disease and Atrial Fibrillation: JACC Review Topic of the Week Comparison of the Efficacy and Safety Outcomes of Edoxaban in 8040 Women Versus 13 065 Men With Atrial Fibrillation in the ENGAGE AF-TIMI 48 Trial Percutaneous Left Atrial Appendage Closure for Stroke Prophylaxis in Patients With Atrial Fibrillation: 2.3-Year Follow-up of the PROTECT AF (Watchman Left Atrial Appendage System for Embolic Protection in Patients With Atrial Fibrillation) Trial Extracellular Vesicles From Epicardial Fat Facilitate Atrial Fibrillation Subclinical and Device-Detected Atrial Fibrillation: Pondering the Knowledge Gap: A Scientific Statement From the American Heart Association Early Rhythm-Control Therapy in Patients with Atrial Fibrillation Edoxaban-based versus vitamin K antagonist-based antithrombotic regimen after successful coronary stenting in patients with atrial fibrillation (ENTRUST-AF PCI): a randomised, open-label, phase 3b trial

Clinical Case Study

JOURNAL:CBSMD Article Link

Clinical Case : Significant LM Diameter Mismatch Treated with IVUS-guidance

Bill Gogas, Fei Ye (syndicatedfeeds)

Pre-reading

Procedure

LTRA 6F JL4 GC w/ Seldinger technique.


Buddy wire technique to cross angulated ostium of LAD w/ Runthrough NS.


Following distal placement of BMW wire, Runtrhough NS was retrieved.


Sequential balloon dilatations w/ 2,5 NC Sprinter Legend from distal to proximal with increasing atmospheres from 10 to 18 was performed. IVUS indicated distal LAD w/ RVD of at least 2,5 mm and proximal LAD media to media diameter of 3,5 mm suggested by IVUS (BS, US) which equals (3,5 mm - 0,25 mm) to vessel diameter of 3,25 mm.


Distal LM PB: 45-50% while proximal LM: >55%.


Distal LAD was treated w/ a 2,5 x 35 DES and mid- to prox-LAD up to distal LM with 3.0 x 28 mm DES*.

*DES of 3.0 or 3.5 mm can be post-dilated up to 4.25 mm



Proximal LAD was post-dilated with 3.0 NC Sprinter balloon to reach expansion of 3,5 mm and LM was post-dilated with 4.0 NC balloon to reach diameter of 4.5 mm.


IVUS confirmed MSAs: LM > 11mm2 & LAD > 7 mm2.


Good angiographic result confirmed by IVUS optimal geometric indices post-stent deployments.



Case Presenter Bill Gogas, Interventional Cardiologist, Visiting Professor of Medicine (Cardiology) at Nanjing First Hospital, China

Case Performed in The Spencer B. King III Catheterization Laboratory

Mentors Spencer B. King III, Shao-liang Chen