Rivaroxaban Is Associated With Higher Rates of Gastrointestinal Bleeding Than Other Direct Oral Anticoagulants: A Nationwide Propensity Score–Weighted Study 2020 ACC Expert Consensus Decision Pathway on Management of Bleeding in Patients on Oral Anticoagulants: A Report of the American College of Cardiology Solution Set Oversight Committee Short-Term Oral Anticoagulation Versus Antiplatelet Therapy Following Transcatheter Left Atrial Appendage Closure Does pulsed field ablation regress over time? A quantitative temporal analysis of pulmonary vein isolation Ablation Versus Drug Therapy for Atrial Fibrillation in Heart Failure Results From the CABANA Trial Percutaneous Left Atrial Appendage Occlusion for Patients in Atrial Fibrillation Suboptimal for Warfarin Therapy: 5-year Results of the PLAATO (Percutaneous Left Atrial Appendage Transcatheter Occlusion) Study 2015 ACC/HRS/SCAI Left Atrial Appendage Occlusion Device Societal Overview Transseptal puncture versus patent foramen ovale or atrial septal defect access for left atrial appendage closure

Clinical Case Study

JOURNAL:CBSMD Article Link

Clinical Case : Significant LM Diameter Mismatch Treated with IVUS-guidance

Bill Gogas, Fei Ye (syndicatedfeeds)

Pre-reading

Procedure

LTRA 6F JL4 GC w/ Seldinger technique.


Buddy wire technique to cross angulated ostium of LAD w/ Runthrough NS.


Following distal placement of BMW wire, Runtrhough NS was retrieved.


Sequential balloon dilatations w/ 2,5 NC Sprinter Legend from distal to proximal with increasing atmospheres from 10 to 18 was performed. IVUS indicated distal LAD w/ RVD of at least 2,5 mm and proximal LAD media to media diameter of 3,5 mm suggested by IVUS (BS, US) which equals (3,5 mm - 0,25 mm) to vessel diameter of 3,25 mm.


Distal LM PB: 45-50% while proximal LM: >55%.


Distal LAD was treated w/ a 2,5 x 35 DES and mid- to prox-LAD up to distal LM with 3.0 x 28 mm DES*.

*DES of 3.0 or 3.5 mm can be post-dilated up to 4.25 mm



Proximal LAD was post-dilated with 3.0 NC Sprinter balloon to reach expansion of 3,5 mm and LM was post-dilated with 4.0 NC balloon to reach diameter of 4.5 mm.


IVUS confirmed MSAs: LM > 11mm2 & LAD > 7 mm2.


Good angiographic result confirmed by IVUS optimal geometric indices post-stent deployments.



Case Presenter Bill Gogas, Interventional Cardiologist, Visiting Professor of Medicine (Cardiology) at Nanjing First Hospital, China

Case Performed in The Spencer B. King III Catheterization Laboratory

Mentors Spencer B. King III, Shao-liang Chen