CBS 2019
CBSMD教育中心
中 文

经皮左心耳封堵

Abstract

Recommended Article

Single direct oral anticoagulant therapy in stable patients with atrial fibrillation beyond 1 year after coronary stent implantation Management and outcomes of patients with left atrial appendage thrombus prior to percutaneous closure Alcohol consumption, cardiac biomarkers, and risk of atrial fibrillation and adverse outcomes Detection of Device-Related Thrombosis Following Left Atrial Appendage Occlusion A Comparison Between Cardiac Computed Tomography and Transesophageal Echocardiography​: A Comparison Between Cardiac Computed Tomography and Transesophageal Echocardiography Frailty and Clinical Outcomes of Direct Oral Anticoagulants Versus Warfarin in Older Adults With Atrial Fibrillation: A Cohort Study Gut microbiota dysbiosis promotes age-related atrial fibrillation by lipopolysaccharide and glucose-induced activation of NLRP3-inflammasome Left Atrial Appendage Occlusion during Cardiac Surgery to Prevent Stroke Left Atrial Appendage Closure versus Non-Warfarin Oral Anticoagulation in Atrial Fibrillation: 4-Year Outcomes of PRAGUE-17

Clinical Case Study

JOURNAL:CBSMD Article Link

Clinical Case : Significant LM Diameter Mismatch Treated with IVUS-guidance

Bill Gogas, Fei Ye (syndicatedfeeds)

Pre-reading

Procedure

LTRA 6F JL4 GC w/ Seldinger technique.


Buddy wire technique to cross angulated ostium of LAD w/ Runthrough NS.


Following distal placement of BMW wire, Runtrhough NS was retrieved.


Sequential balloon dilatations w/ 2,5 NC Sprinter Legend from distal to proximal with increasing atmospheres from 10 to 18 was performed. IVUS indicated distal LAD w/ RVD of at least 2,5 mm and proximal LAD media to media diameter of 3,5 mm suggested by IVUS (BS, US) which equals (3,5 mm - 0,25 mm) to vessel diameter of 3,25 mm.


Distal LM PB: 45-50% while proximal LM: >55%.


Distal LAD was treated w/ a 2,5 x 35 DES and mid- to prox-LAD up to distal LM with 3.0 x 28 mm DES*.

*DES of 3.0 or 3.5 mm can be post-dilated up to 4.25 mm



Proximal LAD was post-dilated with 3.0 NC Sprinter balloon to reach expansion of 3,5 mm and LM was post-dilated with 4.0 NC balloon to reach diameter of 4.5 mm.


IVUS confirmed MSAs: LM > 11mm2 & LAD > 7 mm2.


Good angiographic result confirmed by IVUS optimal geometric indices post-stent deployments.



Case Presenter Bill Gogas, Interventional Cardiologist, Visiting Professor of Medicine (Cardiology) at Nanjing First Hospital, China

Case Performed in The Spencer B. King III Catheterization Laboratory

Mentors Spencer B. King III, Shao-liang Chen